A simple and accurate reversed phase high-performance liquid chromatography coupled with diode array detector (HPLC-DAD) method for simultaneously determining and quantifying the antioxidants carotenes, xanthophylls, and retinol in human plasma is presented in this paper. Compounds were extracted with hexane, a C30 column, and a mobile phase of methanol, methyl tert-butyl ether, and water were used for the separation of the compounds. A total of 8 carotenoids, 3 Z-β-carotene isomers, and 1 fat-soluble vitamin (retinol) were resolved within 72 min at a flow rate of 0.6 mL/min. Detection was achieved at 450 nm for carotenoids and 330 nm for retinol. To evaluate the effectiveness of themethod, it has been applied to an intervention study conducted on eight volunteers. Results. Limits of detection were between 0.1 μg/mL for lycopene and astaxanthin and 1.3 μg/mL for 15-Z-β-carotene. Recoveries were ranged between 89% and 113% for α-carotene and astaxanthin, respectively. Accuracy was between 90.7% and 112.2% and precision was between 1% and 15% RSD. In human plasma samples compounds studied were identified besides three lycopene isomers, demonstrated to be suitable for application in dietary intervention studies. Conclusions. Due to its accuracy, precision, selectivity, and reproducibility, this method is suitable to dietary habits and/or antioxidants status studies.
The concentration of carotenoids and fat-soluble vitamins in human plasma may play a significant role in numerous chronic diseases such as age-related macular degeneration and some types of cancer. Although these compounds are of utmost interest for human health, methods for their simultaneous determination are scarce. A new high pressure liquid chromatography (HPLC)-tandem mass spectrometry (MS/MS) method for the quantification of selected carotenoids and fat-soluble vitamins in human plasma was developed, validated, and then applied in a pilot dietary intervention study with healthy volunteers. In 50 min, 16 analytes were separated with an excellent resolution and suitable MS signal intensity. The proposed HPLC–MS/MS method led to improvements in the limits of detection (LOD) and quantification (LOQ) for all analyzed compounds compared to the most often used HPLC–DAD methods, in some cases being more than 100-fold lower. LOD values were between 0.001 and 0.422 µg/mL and LOQ values ranged from 0.003 to 1.406 µg/mL, according to the analyte. The accuracy, precision, and stability met with the acceptance criteria of the AOAC (Association of Official Analytical Chemists) International. According to these results, the described HPLC-MS/MS method is adequately sensitive, repeatable and suitable for the large-scale analysis of compounds in biological fluids.
trans-Lycopene from TJ may attenuate the risk of cardiovascular disease by reducing the concentration of important inflammatory molecules related to atherosclerosis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.