The Canon OCT-HS100 is a reproducible instrument that matches the Zeiss Cirrus HD-OCT well. It remains to be evaluated how sensitive the Canon OCT-HS100 is to detect small subtle changes in optic disc parameters and macular nerve fiber layer thickness. Furthermore, due to the differences in thickness estimation, it is important to emphasize that SD-OCTs are not interchangeable.
Purpose: To evaluate the precision of individual and combined macula and optic disc volumetric analysis, and the agreement between these two scan modes with spectral domain optical coherence tomography (OCT).Methods: Macular and optic disc volumetric measurements were performed with individual and combined scan protocols in one eye of 75 healthy subjects. Three repeated measurements were performed with each protocol. From the macular area, retinal thickness in nine different sectors and ganglion cell complex thickness in eight different sectors were analyzed from both scan modes. From the optic disc area, the peripapillary retinal nerve fiber layer (pRNFL) thickness in 12 clock sectors and the optic disc parameters were evaluated. For all the parameters, repeatability limit and agreement analysis were performed.Results: For the retinal thickness measurements in macula, the combined scan had two to three times larger repeatability limit than the individual scan for all the sectors except the central sector, where the repeatability limit was five times larger. The limits of agreement intervals were lower than 20 μm for all sectors, except the central. The ganglion cell complex measurements also had larger repeatability limits for the combined scans, and the limits of agreement intervals were <10 μm for all sectors. For the pRNFL thickness, the repeatability values were distributed like a vertically elongated ellipse for both scans, but still the repeatability was better for individual scan compared to the combined scan. The shortest and widest interval are obtained for sectors 9 (9 μm) and 12 (40 μm), respectively. The repeatability limit was <0.15 units for all disc parameters with both scan modes.Conclusion: The individual macula and optic disc scans had better repeatability than the combined scan mode, and the two scan modes cannot be used interchangeability due to the wide limits of agreement.
The aim of the present project was to investigate accommodative behavior in young adults and adolescents fitted with an aspheric multifocal (center distance) contact lens with focus on evaluating whether these lenses can be an alternative treatment for subjects in which a reduced level of blur and thereby accommodation in near vision is aimed at. Twenty normal subjects aged between 21 and 35 years participated in the study. Aberrometry was perfomed using a Zywave TM aberrometer, first on the uncorrected eyes of all subjects, and again while the subjects wore a multifocal contact lens with a þ1.00 add. A Shin-Nippon N Vision-K 5001 Autoref-Keratometer was used to measure accommodative response with two different refractive corrections: (1) habitual spectacle correction only, and (2) habitual correction and a aspheric multifocal (center distance) contact lens. Four hours of adaptation to the lens was allowed. The lag when wearing only the habitual spectacles was compared with the lag while wearing both the habitual spectacles and the aspheric multifocal contact lens. The mean lag of accommodation for the subject group was 0.85 D (AE0.57 SD) and 0.75 D (AE0.52 SD) without and with the multifocal lens, respectively. Statistical analyses showed no difference in lag (t ¼ 0.8479, p ¼ 0.407) with and without the lens. In conclusion, young normal subjects do not relax accommodation when fitted with aspheric multifocal center distance lenses when the addition is þ1.00. It is therefore unlikely that subjects with accommodative ability, in whom the treatment purpose is to reduce blur and thereby accommodation, can be effectively treated with such lenses.
Most scientists agree that dyslexia is mainly a phonological impairment. Nevertheless, the results show that vergence treatment might help dyslexics. Larger studies are required to provide guidance in this area.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.