The design, energetic performance, and thermal impact of large-scale geothermal collector systems (LSCs) are dependent on the thermal conductivity of unsaturated soils (λ). The aim of this study was to investigate the benefits of two different λ measurement methods using single-needle sensor measuring devices on a laboratory scale. Since large-scale determinations are required in the context of LSCs, the potential for deriving λ from electrical resistivity tomography measurements (ERTs) was also examined. Using two approaches—the continuous evaporation method and the punctual method—thermal conductivities of soil samples from Bad Nauheim (Germany) were measured. The results were compared with averaged λ derived from three ERT sections. With the evaporation method, significant bulk density changes were observed during the experimental procedure, which were caused by the clay content and the use of repacked samples. The punctual method ensures a sufficiently constant bulk density during the measurements, but only provides a small number of measurement points. The thermal conductivities derived from ERTs show largely minor deviations from the laboratory measurements on average. If further research confirms the results of this study, ERTs could provide a non-invasive and unelaborate thermal exploration of the subsurface in the context of large-scale infrastructure projects such as LSCs.
Groundwater temperature (GWT) is usually measured using screened monitoring wells (MWs). The aim of this study was to investigate whether MWs are suitable for monitoring the effects of large-scale geothermal collector systems (LSCs) on GWT, focusing on possible vertical flows within the MWs due to both natural and forced convection. Comparative temperature depth profiles were therefore recorded over a period of nine months in both shallow MWs and in small-diameter, non-screened temperature monitoring stations (TMSs), each of which was installed in a single borehole. Particularly high temperature deviations were measured in MWs in the upper part of the water column where the GWT reached up to 1.8 K warmer than in the surrounding subsurface. These deviations correlate unambiguously with the prevailing positive thermal gradients and are caused by thermal convection. Where forced convection occurred, the GWT was measured to be up to 0.8 K colder. Potential temperature deviations must be considered when monitoring very shallow GWT as thermal gradients can be particularly high in these zones. For monitoring concepts of LSCs, a combination of MW and TMS is proposed for GWT measurements decoupled by the effects of convection and in order to enable further investigations such as pumping tests.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.