We present preliminary diameters and albedos for 13511 MBAs that were observed during the 3-Band Cryo phase of the WISE survey (after the outer cryogen tank was exhausted) and as part of the NEOWISE Post-Cryo Survey (after the inner cryogen tank was exhausted). With a reduced or complete loss of sensitivity in the two long wavelength channels of WISE, the uncertainty in our fitted diameters and albedos is increased to ∼ 20% for diameter and ∼ 40% for albedo. Diameter fits using only the 3.4 and 4.6 µm channels are shown to be dependent on the literature optical H absolute magnitudes. These data allow us to increase the number of size estimates for large MBAs which have been identified as members of dynamical families. We present thermal fits for 14 asteroids previously identified as the parents of a dynamical family that were not observed during the fully cryogenic mission.
Building on the successful development of the 10 µm HgCdTe detector arrays for the proposed NEOCam mission, the University of Rochester Infrared Detector team and Teledyne Imaging Systems are working together to extend the cutoff wavelength of HgCdTe detector arrays initially to 13 µm, with the ultimate goal of developing 15 µm HgCdTe detector arrays for space and ground-based astronomy. The advantage of HgCdTe detector arrays is that they can operate at higher temperatures than the currently used arsenic doped silicon detector arrays at the longer wavelengths. Our infrared detector team at the University of Rochester has received and tested four 13 µm detector arrays from Teledyne Imaging Systems with three different pixel designs, two of which are meant to reduce quantum tunneling dark current. The pixel design of one of these arrays has mitigated the effects of quantum tunneling dark currents for which we have been able to achieve, at a temperature of 28 K and applied bias of 350 mV, a well depth of at least 75 ke − for 90% of the pixels with a median dark current of 1.8 e − /sec. These arrays have demonstrated encouraging results as we move forward to extending the cutoff wavelength to 15 µm.
The University of Rochester infrared detector group is working together with Teledyne Imaging Sensors to develop HgCdTe 15 µm cutoff wavelength detector arrays for future space missions. To reach the 15 µm cutoff goal, we took an intermediate step by developing four ∼13 µm cutoff wavelength arrays to identify any unforeseen effects related to increasing the cutoff wavelength from the extensively characterized 10 µm cutoff wavelength detector arrays developed for the NEOCam mission. The characterization of the ∼13 µm cutoff wavelength HgCdTe arrays at the University of Rochester allowed us to determine the key dark current mechanisms that limit the performance of these HgCdTe detector arrays at different temperatures and bias when the cutoff wavelength is increased. We present initial dark current and well depth measurements of a 15 µm cutoff array which shows dark current values two orders of magnitude smaller at large reverse bias than would be expected from our previous best structures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.