Chikungunya fever has spread through several Indian Ocean islands and India, including popular travel destinations. To compare usefulness of diagnostic tests and to understand reasons for the magnitude and severity of an outbreak, we used 3 diagnostic methods to test 720 samples from 680 patients returning to Europe from the Indian Ocean region in 2006. Chikungunya infection was confi rmed for 24.4% patients in the fi rst half of the year and for 9.9% in the second half. Reverse transcription-PCR was positive for all samples taken up to day 4 after symptom onset. Immunofl uorescence detected immunoglobulin (Ig) M on day 1 and IgG on day 2 for some patients, and in all patients from day 5 onward. Soon after onset of symptoms, patients had IgG and IgM and high viral loads (some >10 9 copies/mL plasma). These data will help healthcare providers select diagnostic tests for returning travelers.
The magnitude of the 2022 multi-country monkeypox virus (MPXV) outbreak has surpassed any preceding outbreak. It is unclear whether asymptomatic or otherwise undiagnosed infections are fuelling this epidemic. In this study, we aimed to assess whether undiagnosed infections occurred among men attending a Belgian sexual health clinic in May 2022. We retrospectively screened 224 samples collected for gonorrhea and chlamydia testing using an MPXV PCR assay and identified MPXV-DNA-positive samples from four men. At the time of sampling, one man had a painful rash, and three men had reported no symptoms. Upon clinical examination 21–37 days later, these three men were free of clinical signs, and they reported not having experienced any symptoms. Serology confirmed MPXV exposure in all three men, and MPXV was cultured from two cases. These findings show that certain cases of monkeypox remain undiagnosed and suggest that testing and quarantining of individuals reporting symptoms may not suffice to contain the outbreak.
Serological diagnosis of Zika virus (ZIKV) infections is challenging due to high cross-reactivity between flaviviruses. We evaluated the diagnostic performance of a novel anti-ZIKV ELISA based on recombinant ZIKV non-structural protein 1 (NS1). Assay sensitivity was examined using sera from 27 patients with reverse transcription (RT)-PCR-confirmed and 85 with suspected ZIKV infection. Specificity was analysed using sera from 1,015 healthy individuals. Samples from 252 patients with dengue virus (n = 93), West Nile virus (n = 34), Japanese encephalitis virus (n = 25), chikungunya virus (n = 19) or Plasmodium spp. (n = 69) infections and from 12 yellow fever-vaccinated individuals were also examined. In confirmed ZIKV specimens collected ≥ 6 days after symptom onset, ELISA sensitivity was 58.8% (95% confidence interval (CI): 36.0–78.4) for IgM, 88.2% (95% CI: 64.4–98.0) for IgG, and 100% (95% CI: 78.4–100) for IgM/IgG, at 99.8% (95% CI: 99.2–100) specificity. Cross-reactivity with high-level dengue virus antibodies was not detected. Among patients with potentially cross-reactive antibodies anti-ZIKV positive rates were 0.8% (95% CI: 0–3.0) and 0.4% (95% CI: 0–2.4) for IgM and IgG, respectively. Providing high specificity and low cross-reactivity, the NS1-based ELISA has the potential to aid in counselling patients, pregnant women and travellers after returning from ZIKV-endemic areas.
BackgroundThe prozone effect (or high doses-hook phenomenon) consists of false-negative or false-low results in immunological tests, due to an excess of either antigens or antibodies. Although frequently cited as a cause of false-negative results in malaria rapid diagnostic tests (RDTs), especially at high parasite densities of Plasmodium falciparum, it has been poorly documented. In this study, a panel of malaria RDTs was challenged with clinical samples with P. falciparum hyperparasitaemia (> 5% infected red blood cells).MethodsTwenty-two RDT brands were tested with seven samples, both undiluted and upon 10 ×, 50 × and 100 × dilutions in NaCl 0.9%. The P. falciparum targets included histidine-rich protein-2 (HRP-2, n = 17) and P. falciparum-specific parasite lactate dehydrogenase (Pf-pLDH, n = 5). Test lines intensities were recorded in the following categories: negative, faint, weak, medium or strong. The prozone effect was defined as an increase in test line intensity of at least one category after dilution, if observed upon duplicate testing and by two readers.ResultsSixteen of the 17 HRP-2 based RDTs were affected by prozone: the prozone effect was observed in at least one RDT sample/brand combination for 16/17 HRP-2 based RDTs in 6/7 samples, but not for any of the Pf-pLDH tests. The HRP-2 line intensities of the undiluted sample/brand combinations with prozone effect (n = 51) included a single negative (1.9%) and 29 faint and weak readings (56.9%). The other target lens (P. vivax-pLDH, pan-specific pLDH and aldolase) did not show a prozone effect.ConclusionThis study confirms the prozone effect as a cause of false-negative HRP-2 RDTs in samples with hyperparasitaemia.
BackgroundMalaria Rapid Diagnostic Tests (RDTs) are widely used for diagnosing malaria. The present retrospective study evaluated the CareStart™ Malaria HRP-2/pLDH (Pf/pan) Combo Test targeting the Plasmodium falciparum specific antigen histidine-rich protein (HRP-2) and the pan-Plasmodium antigen lactate dehydrogenase (pLDH) in a reference setting.MethodsThe CareStart™ Malaria HRP-2/pLDH (Pf/pan) Combo Test was evaluated on a collection of samples obtained in returned international travellers using microscopy corrected by PCR as the reference method. Included were P. falciparum (n = 320), Plasmodium vivax (n = 76), Plasmodium ovale (n = 76), Plasmodium malariae (n = 23) and Plasmodium negative samples (n = 95).ResultsOverall sensitivity for the detection of P. falciparum was 88.8%, increasing to 94.3% and 99.3% at parasite densities above 100 and 1,000/μl respectively. For P. vivax, P. ovale and P. malariae, overall sensitivities were 77.6%, 18.4% and 30.4% respectively. For P. vivax sensitivity reached 90.2% for parasite densities above 500/μl. Incorrect species identification occurred in 11/495 samples (2.2%), including 8/320 (2.5%) P. falciparum samples which generated only the pan-pLDH line. For P. falciparum samples, 205/284 (72.2%) HRP-2 test lines had strong or medium line intensities, while for all species the pan-pLDH lines were less intense, especially in the case of P. ovale. Agreement between observers was excellent (kappa values > 0.81 for positive and negative readings) and test results were reproducible. The test was easy to perform with good clearing of the background.ConclusionThe CareStart™ Malaria HRP-2/pLDH (Pf/pan) Combo Test performed well for the detection of P. falciparum and P. vivax, but sensitivities for P. ovale and P. malariae were poor.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.