Background: Occult organizational structures in DNA sequences may hold the key to understanding functional and evolutionary aspects of the DNA molecule. Such structures can also provide the means for identifying and discriminating organisms using genomic data. Species specific genomic signatures are useful in a variety of contexts such as evolutionary analysis, assembly and classification of genomic sequences from large uncultivated microbial communities and a rapid identification system in health hazard situations.
Highly doped or alloyed Gd2O3 in HfO2 films form heterojunction diodes with silicon. Single neutron capture events can be identified with a Hf0.85Gd0.15O1.93 to n-type silicon heterojunction. With long pulse integration times and suppression of the smaller pulses, there is agreement between the key pulse height spectral features and those predicted by Monte Carlo simulations. The latter align very well with the decay channels of the Gd following neutron capture, particularly those involving the Gd K-shell Auger electron resonances.
This paper presents the design and test results of a computational radiation sensor system based on a single chip solution that can determine the direction of gamma rays emitted from a radiation source. The overall system is formed by merging a sensor section with a compact and low power computational radiation sensor section. The sensor section houses three NaI gamma ray detectors arranged in a spatial configuration that allows for direction finding. The computational sensor is based on a single chip solution developed by authors that houses multiple low power sensor front ends, event driven analog-todigital converters, and a dedicated microcontroller on the same die. The presented system is capable of gathering the pulse height spectra from the gamma isotope data received from the three separate NaI detectors. Further processing of the data is possible by executing software algorithms using the computation resources available on chip. To that end, a compact fixed-point program was developed to perform on-chip real-time gamma ray collection and direction estimation. The single chip solution was fabricated in a 0.18 μm CMOS technology with field tests demonstrating the validity of the approaches taken. The total computational sensor system power consumption is less than 20 μW, excluding the detector power consumption. The gamma isotope direction finding program executes in less than 1 ms with 5 • accuracy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.