Aims: To characterize the composition of microbial populations in a distribution system simulator (DSS) by direct sequence analysis of 16S rDNA clone libraries. Methods and Results: Bacterial populations were examined in chlorinated distribution water and chloraminated DSS feed and discharge water. Bacterial strains isolated from DSS discharge water on R2A medium were identified using 16S rDNA sequence analysis. The majority of the bacteria identified were a-proteobacteria, ranging from approx. 34% in the DSS discharge water to 94% of the DSS isolates. Species richness estimators Chao1 and ACE (abundance-based coverage estimators) indicated that the chlorinated distribution water sample was representative of the total population diversity, while the chloraminated DSS feed water sample was dominated by Hyphomicrobium sp. sequences. The DSS discharge water contained the greatest diversity of a-, b-, cproteobacteria, with 36% of the sequences being operational taxonomic units (OTUs, sequences with >97AE0% homology). Conclusions: This work demonstrated the dominance of a-proteobacteria in distribution system water under two different disinfectant residuals. The shift from chlorine to monochloramine residual may have played a role in bacterial population dynamics. Significance and Impact of the Study: Accurate identification of bacteria present in treated drinking water is needed in order to better determine the risk of regrowth of potentially pathogenic organisms within distribution systems.
There are numerous PCR-based assays available to characterize human fecal pollution in ambient waters. Each assay employs distinct oligonucleotides and many target different genes and microorganisms leading to potential variations in assay performance. Performance comparisons utilizing feces and raw sewage samples are needed to determine which assays are best suited for expensive and time-consuming field validation, fate, transport, and epidemiology studies. We report the assessment of five end-point PCR and 10 real-time quantitative PCR (qPCR) assays that target genes from presumptive Bacteroidales microorganisms reported to be associated with human feces. Each assay was tested against a reference collection of 54 primary influent sewage samples collected from different geographical locations across the United States and 174 fecal DNA extracts from 23 different animal sources. Experiments indicate that human-associated genetic markers are distributed across a broad range of human populations but show substantial differences in specificity for human feces suggesting that particular assays may be more suitable than others depending on the abundance of genetic marker required for detection and the animal sources impacting a particular watershed or beach of interest.
An innovative approach to increase biofuel feedstock lipid yields from municipal sewage sludge via manipulation of carbon-to-nitrogen (C:N) ratio and glucose loading in activated sludge bioreactors was investigated. Sludge lipid and fatty acid methyl ester (biodiesel) yields (% cell dry weight, CDW) were enhanced via cultivation in activated sludge bioreactors operated at high initial C:N ratio (!40:1) and glucose loading (!40 g L À1 ). Under C:N 70, 60 g L À1 glucose loading, a maximum of 17.5 AE 3.9 and 10.2 AE 2.0% CDW lipid and biodiesel yields, respectively, were achieved after 7 d of cultivation. The cultured sludge lipids contained mostly C 16 AC 18 fatty acids, with oleic acid consistently accounting for 40-50% of the total fatty acids. Microbial composition in activated sludge exposed to C:N 70 shifted toward specific gammaproteobacteria, suggesting their relevance in lipid production in wastewater microbiota and potential value in biofuel synthesis applications.
Diffuse sources of human fecal pollution allow for the direct discharge of waste into receiving waters with minimal or no treatment. Traditional culture-based methods are commonly used to characterize fecal pollution in ambient waters, however these methods do not discern between human and other animal sources of fecal pollution making it difficult to identify diffuse pollution sources. Human-associated quantitative real-time PCR (qPCR) methods in combination with low-order headwatershed sampling, precipitation information, and high-resolution geographic information system land use data can be useful for identifying diffuse source of human fecal pollution in receiving waters. To test this assertion, this study monitored nine headwatersheds over a two-year period potentially impacted by faulty septic systems and leaky sanitary sewer lines. Human fecal pollution was measured using three different human-associated qPCR methods and a positive significant correlation was seen between abundance of human-associated genetic markers and septic systems following wet weather events. In contrast, a negative correlation was observed with sanitary sewer line densities suggesting septic systems are the predominant diffuse source of human fecal pollution in the study area. These results demonstrate the advantages of combining water sampling, climate information, land-use computer-based modeling, and molecular biology disciplines to better characterize diffuse sources of human fecal pollution in environmental waters.
Most water utilities use chlorine or chloramine to produce potable water. These disinfecting agents react with water to produce residual oxidants within a water distribution system (WDS) to control bacterial growth. While monochloramine is considered more stable than chlorine, little is known about the effect it has on WDS biofilms. Community structure of 10-week old WDS biofilms exposed to disinfectants was assessed after developing model biofilms from unamended distribution water. Four biofilm types were developed on polycarbonate slides within annular reactors while receiving chlorine, chloramine, or inactivated disinfectant residual. Eubacteria were identified through 16S rDNA sequence analysis. The model WDS biofilm exposed to chloramine mainly contained Mycobacterium and Dechloromonas sequences, while a variety of alpha- and additional beta-proteobacteria dominated the 16S rDNA clone libraries in the other three biofilms. Additionally, bacterial clones distantly related to Legionella were found in one of the biofilms receiving water with inactivated chlorine residual. The biofilm reactor receiving chloraminated water required increasing amounts of disinfectant after 2 weeks to maintain chlorine residual. In contrast, free chlorine residual remained steady in the reactor that received chlorinated water. The differences in bacterial populations of potable water biofilms suggest that disinfecting agents can influence biofilm development. These results also suggest that biofilm communities in distribution systems are capable of changing in response to disinfection practices.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.