This review covers the occurrence of aluminium in soil, air, water and food. In addition, aluminium levels in body tissues and its movement within the body have been considered. The adverse effects of aluminium that have been reported in recent years include Alzheimer's disease, dementia and hyperactivity and learning disorders in children.
Lee County Utilities (LCU) undertook a comprehensive study of sulfide generation, corrosion, and odor in the 80 square mile collection system serving Fort Myers and Lee County. Due to long collection system detention times, numerous pump stations, and elevated wastewater temperatures, high concentrations of dissolved sulfide form in the force mains. Dissolved sulfide concentrations as high as 40 mg/l and hydrogen sulfide concentrations as high as 260 ppm were measured. Much of the system consists of long force mains with numerous contributing pump stations forming a 'manifold', with few 'master stations' carrying large flows. Hydrogen peroxide, calcium nitrate, and iron salts are currently used for sulfide control, at a total of 18 locations, for an annual cost of $1.2 million. Additionally, 24 pump stations have odor control systems.The system-wide sulfide control plan is intended to meet the following objectives: Meet a zero-tolerance requirement for odor complaints Protect vulnerable assets, such as ductile iron and concrete pipelines and pump stations Optimize the use of sulfide control chemicals to maintain a cost-effective programThe field activities included grab samples for dissolved sulfides, pH, dissolved oxygen, wastewater temperature, and headspace hydrogen sulfide concentrations in addition to corrosion assessments at 320 pump stations in six of the county's collection systems. Odalogs were installed at selected stations to record diurnal trends. At ten of the pump stations, Odalogs were deployed simultaneously with ISCO 24-hr sequential samplers for analysis of dissolved sulfide. The 24 bottles were analyzed in the field as soon as the sampler was turned off. The intention was to produce a useful regression relationship between sulfide and headspace hydrogen sulfide.In order to determine optimal chemical dosage, mass flow of sulfide from major pump stations had to be determined. Pump station flow rates were not readily available so they were calculated by measuring the rate of water level drawdown in the wet well. Additionally, at eight pump stations, In-Situ Troll level logger probes were deployed. These probes logged wastewater levels of the pump stations at 5-second intervals. The level data was processed to generate profiles of wastewater pumping rates and calculate the volumes of wastewater handled by the pump stations over the course of a day. The results showed significant variation in pumping rate from one pump cycle to another. This was because of varying back-pressure in the force main due to the
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.