Gas exchange in premature neonates is regularly impaired by structural and functional immaturity of the lung. Mechanical ventilation, which is vitally important to sustain oxygenation and CO(2) elimination, causes, at the same time, mechanical and inflammatory destruction of lung tissue. To date, extracorporeal oxygenation is not a treatment option, one reason among others being the size of available oxygenators and cannulas. We hypothesized that a substantial improvement in gas exchange can be achieved by maintenance of the fetal cardiopulmonary bypass and interposition of a suitable passively driven (arteriovenous) membrane oxygenator. In close cooperation between engineers and neonatologists, we developed a miniaturized oxygenator and adapted cannulas to be used as a pumpless extracorporeal lung support that is connected to the circulation via cannulation of the umbilical cord vessels. First in vitro and in vivo studies show promising results. We regard this as one step on the way to clinical application of the artificial placenta.
The concept of an artificial placenta has been pursued in experimental research since the early 1960s. The principle has yet to be successfully implemented in neonatal care despite the constant evolution in extracorporeal life support technology and advancements in neonatal intensive care in general. For more than three decades, the physical dimensions of the required equipment necessitated pump-driven circuits; however, recent advances in oxygenator technology have allowed exploration of the simpler and physiologically preferable concept of pumpless arteriovenous oxygenation. We expect that further miniaturization of the extracorporeal circuit will allow the implementation of the concept into clinical application as an assist device. To this end, NeonatOx (Fig. 1), a custom-made miniaturized oxygenator with a filling volume of 20 mL, designed by our own group, has been successfully implemented with a preterm lamb model of less than 2000 g body weight as an assist device. We provide an overview of milestones in the history of extracorporeal membrane oxygenation of the preterm newborn juxtaposed against current and future technological advancements. Key limitations, which need to be addressed in order to make mechanical gas exchange a clinical treatment option of prematurity-related lung failure, are also identified.
The artificial placenta as a fascinating treatment alternative for neonatal lung failure has been the subject of clinical research for over 50 years. Pumpless systems have been in use since 1986. However, inappropriate dimensioning of commercially available oxygenators has wasted some of the theoretical advantages of this concept. Disproportional shunt fractions can cause congestive heart failure. Blood priming of large oxygenators and circuits dilutes fetal hemoglobin (as the superior oxygen carrier), is potentially infectious, and causes inflammatory reactions. Flow demands of large extracorporeal circuits require cannula sizes that are not appropriate for use in preterm infants. NeonatOx, a tailored low-volume oxygenator for this purpose, has proven the feasibility of this principle before. We now report the advances in biological performance of a refined version of this specialized oxygenator.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.