The objective of the present study is to evaluate how the elastic properties of the fabrication material of dental implants influence peri-implant bone load transfer in terms of the magnitude and distribution of stress and deformation. A three-dimensional (3D) finite element analysis was performed; the model used was a section of mandibular bone with a single implant containing a cemented ceramic-metal crown on a titanium abutment. The following three alloys were compared: rigid (Y-TZP), conventional (Ti-6Al-4V), and hyperelastic (Ti-Nb-Zr). A 150-N static load was tested on the central fossa at 6° relative to the axial axis of the implant. The results showed no differences in the distribution of stress and deformation of the bone for any of the three types of alloys studied, mainly being concentrated at the peri-implant cortical layer. However, there were differences found in the magnitude of the stress transferred to the supporting bone, with the most rigid alloy (Y-TZP) transferring the least stress and deformation to cortical bone. We conclude that there is an effect of the fabrication material of dental implants on the magnitude of the stress and deformation transferred to peri-implant bone.
Objective. Long-term clinical data on the success and complication rates of monolithic or minimally veneered zirconia implant-supported restorations are lacking. Hence, the purpose of this retrospective clinical study was to analyze the complications of monolithic or partially veneered zirconia implant-supported restorations up to 5 years follow-up. Material and Methods. Single crowns, bridges, and full-arch rehabilitations were included. The selection process was achieved by reviewing data from the prosthetic laboratory and excluding cases in which zirconium and full-ceramic coating restorations were used. A total of 154 restorations were included (82 monolithic and 72 with buccal ceramic stratification). All the complications encountered, and the solutions applied, were explained. Results. A total of 93 restorative units had a follow-up of between 24 and 60 months, and 61 restoration units had a follow-up of between 12 and 24 months. A total of 7 complications were encountered (14.58% of cases; 95.45% per prosthetic unit). The technical complication rate was 2.08% (one case of minor chipping in one prosthetic unit); regarding the mechanical complications, four decementations (8.33% of the cases) and two screw loosening (4.17% of the cases) were encountered. Conclusions. Considering the limitations of this study, it can be concluded that monolithic or partially veneered zirconia implant-supported restorations have a good clinical behavior during a follow-up period of up to 5 years.
BackgroundThis study evaluated the influence of implant site preparation depth on primary stability measured by insertion torque and resonance frequency analysis (RFA).Material and MethodsThirty-two implant sites were prepared in eight veal rib blocks. Sixteen sites were prepared using the conventional drilling sequence recommended by the manufacturer to a working depth of 10mm. The remaining 16 sites were prepared using an oversize drilling technique (overpreparation) to a working depth of 12mm. Bone density was determined using cone beam computerized tomography (CBCT). The implants were placed and primary stability was measured by two methods: insertion torque (Ncm), and RFA (implant stability quotient [ISQ]).ResultsThe highest torque values were achieved by the conventional drilling technique (10mm). The ANOVA test confirmed that there was a significant correlation between torque and drilling depth (p<0.05). However, no statistically significant differences were obtained between ISQ values at 10 or 12 mm drilling depths (p>0.05) at either measurement direction (cortical and medullar). No statistical relation between torque and ISQ values was identified, or between bone density and primary stability (p
>0.05).ConclusionsVertical overpreparation of the implant bed will obtain lower insertion torque values, but does not produce statistically significant differences in ISQ values.
Key words:Implant stability quotient, overdrilling, primary stability, resonance frequency analysis, torque.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.