Background: The novel cystic fibrosis transmembrane conductance regulator (CFTR) modulators, ivacaftor, lumacaftor, and tezacaftor, are the first drugs directly targeting the underlying pathophysiological mechanism in cystic fibrosis (CF); however, independent studies describing their pharmacokinetics are lacking. The aim of this study was to develop a quantification method for ivacaftor and its 2 main metabolites, lumacaftor and tezacaftor, in plasma and sputum using liquid chromatography with tandem mass spectrometry. Methods: The developed method used a small sample volume (20 µL) and simple pretreatment method; protein precipitation solution and internal standard were added in one step to each sample. Liquid chromatography with tandem mass spectrometry was performed for a total run time of 6 minutes. The method was validated by assessing selectivity, carryover, linearity, accuracy and precision, dilution, matrix effects, and stability. Results: The selectivity was good as no interference from matrices was observed. In the concentration range from 0.01 to 10.0 mg/L, calibration curves were linear with a correlation coefficient >0.9997 for all compounds. The within-run and between-run accuracy were between 99.7% and 116% at the lower limit of quantitation (LLOQ) and between 95.8% and 112.9% for all concentrations above LLOQ for all analytes in plasma and sputum. Within-run and between-run precisions were <12.7% for LLOQ and <6.7% for the higher limit of quantitation. Samples were stable, with no significant degradation at examined temperatures and time points. Clinical applicability was revealed by analyzing samples from 2 patients with CF. Conclusions: The presented method enables simultaneous quantification of ivacaftor, lumacaftor, and tezacaftor in plasma and sputum and is an improvement over previous methods because it uses smaller sample volumes, a simple pretreatment protocol, and includes tezacaftor. In future studies, it can be applied for examining pharmacokinetics characteristics of new CF transmembrane conductance regulator modulators.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.