Context. Until recently, camera networks designed for monitoring fireballs worldwide were not fully automated, implying that in case of a meteorite fall, the recovery campaign was rarely immediate. This was an important limiting factor as the most fragile – hence precious – meteorites must be recovered rapidly to avoid their alteration. Aims. The Fireball Recovery and InterPlanetary Observation Network (FRIPON) scientific project was designed to overcome this limitation. This network comprises a fully automated camera and radio network deployed over a significant fraction of western Europe and a small fraction of Canada. As of today, it consists of 150 cameras and 25 European radio receivers and covers an area of about 1.5 × 106 km2. Methods. The FRIPON network, fully operational since 2018, has been monitoring meteoroid entries since 2016, thereby allowing the characterization of their dynamical and physical properties. In addition, the level of automation of the network makes it possible to trigger a meteorite recovery campaign only a few hours after it reaches the surface of the Earth. Recovery campaigns are only organized for meteorites with final masses estimated of at least 500 g, which is about one event per year in France. No recovery campaign is organized in the case of smaller final masses on the order of 50 to 100 g, which happens about three times a year; instead, the information is delivered to the local media so that it can reach the inhabitants living in the vicinity of the fall. Results. Nearly 4000 meteoroids have been detected so far and characterized by FRIPON. The distribution of their orbits appears to be bimodal, with a cometary population and a main belt population. Sporadic meteors amount to about 55% of all meteors. A first estimate of the absolute meteoroid flux (mag < –5; meteoroid size ≥~1 cm) amounts to 1250/yr/106 km2. This value is compatible with previous estimates. Finally, the first meteorite was recovered in Italy (Cavezzo, January 2020) thanks to the PRISMA network, a component of the FRIPON science project.
Two meteorite pieces have been recovered in Italy, near the town of Cavezzo (Modena), on 4th January 2020. The associated fireball was observed on the evening of New Year’s Day 2020 by eight all-sky cameras of the PRISMA fireball network, a partner of FRIPON. The computed trajectory had an inclination angle of approximately 68○ and a velocity at infinity of 12.8 km s−1. Together with the relatively low terminal height, estimated as 21.5 km, those values were indicating the significant possibility of a meteorite dropping event, as additionally confirmed by the non zero residual total mass. The strewn-field was computed taking into account the presence of two bright light flashes, revealing that the meteoroid had been very likely subject to fragmentation. Three days after the event, two samples, weighing 3.1 g and 52.2 g, were collected as a result of a dedicated field search and thanks to the involvement of the local people. The two pieces were immediately recognised as freshly fallen fragments of meteorite. The computed orbital elements, compared with the ones of known Near-Earth Asteroids from the NEODyS database, are compatible with one asteroid only; 2013 VC10. The estimated original mass of the meteoroid, 3.5 kg, and size, approximately 13 cm, is so far the smallest among the current 35 cases in which meteorites were recovered from precise strewn-field computation thanks to observational data. This result demonstrates the effectiveness of accurate processing of fireball network data even on challenging events generated by small size meteoroids.
PURPOSE: To assess the tensile strength of polypropylene and polypropylene associated with polyglactin meshes (Vypro II® - Ethicon®, Somerville, NJ, USA) in a situation of partial separation of abdominal muscle aponeurosis on rats. METHODS: Thirty rats were used of the Wistar strain, which were randomized into two groups of 15 specimens each. In both groups an aponeurotic-muscle deformity was created on the abdominal wall measuring 3.0 x 1.0 cm, which was closed with polypropylene mesh (polypropylene group) or Vypro® mesh (vypro group). After 28 days the rats underwent euthanasia and an area was removed from the abdominal wall with which a strip was made measuring 2.0 cm in length and 6.0 cm in width comprising the abdominal muscles with the implanted mesh. This sample was placed in a mechanical test machine in which a constant force was applied contrary to the tissue strips. Maximum force expressed in Newton was considered until full rupture of the sample occurred. The non-parametric Kruskal - Wallis test was used for statistical analysis admitting p<0.05. RESULTS: Out of the thirty animals, there were two deaths in the vypro group and one unit in the polypropylene group was lost. One animal in the polypropylene group developed hernia during the study and another one developed granuloma of the abdominal wall. All animals in both groups developed epiplon adherence to the mesh. The average force was 48.08 N for the polypropylene group and 45.32 for the vypro® group. CONCLUSION: In these experimental conditions it could be observed that there is no statistically significant difference in the rupture force of the polypropylene and Vypro® meshes (p=0.54).
The utilization of a mechanical test machine is a useful tool in the assessment of materials' strength, providing accurate results. Nevertheless the trials must be well structured analyzing the multiple variables so as to attain a pattern of constant reproducibility and to provide the necessary reliability.
PURPOSE: To study the tensile strength of the abdominal wall following laparotomy synthesis utilizing three types of surgical wires. METHODS: Thirty Wistar rats were randomized into three groups of ten rats each. Each group underwent a 3cm-laparotomy which was closed with 3-0 polyglactin 910, polyglecrapone and catgut wires. After 63 days, euthanasia was performed and part of the abdominal wall was removed with which a strip was produced measuring 2.0 cm in length by 6.0 cm in width comprising the abdominal muscles with the implanted mesh. The sample was fixed in a mechanical test machine in which constant force was applied contrary to the tissue strips. Maximum force was considered, expressed in Newton, until full rupture of the tissue occurred. The non-parametrical Kruskal - Wallis test was used for the statistical analysis, admitting p<0.05. RESULTS: The average strength of the catgut group was slightly lower (33.50 N) than that of the polyglactin group (34.23 N), the difference not being statistically significant (p=0.733). The polyglecaprone group was the one which presented the lowest strength value of all three wires analyzed (29.86 N). No statistical difference was obtained when comparing the strength values of the polyglecaprone group and the catgut group (p=0.06 ). However, when the polyglecaprone group was compared to the polyglactin 910 group no statistical difference was obtained (p=0.029). CONCLUSION: The polyglactin wire presented the highest tensile strength among the three wires analyzed, such value being statistically significant when polyglactin was compared to the polyglecaprone wire.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.