Real-time determination of Kt/V can be provided by monitoring ultraviolet absorbance of solutes in spent dialysate. This not only overcomes dependency on errorprone pre-and post-dialysis blood sampling; it circumvents inaccuracies associated with estimating the urea distribution volume and its high measurement frequency tightly reflects the course of the dialysis. Our study compared the ultraviolet-based spKt/V and eKt/V with the commonly used blood-based counterparts. A first study of 16 patients compared ultraviolet Kt/Vs against blood Kt/Vs obtained by using the 'gold standard' of serial blood samples. A second study included 18 patients and compared the ultraviolet and blood values under routine conditions. Both studies showed mean blood-based spKt/V and eKt/V values statistically indistinguishable from their ultraviolet-based counterparts. Hence, on-line monitoring of ultraviolet absorption of spent dialysate is applicable in routine hemodialysis allowing continuous measure of removed solutes from spent dialysate without disturbing the patient or treatment session.
To date, single‐needle (SN) hemodialysis (HD) requires a dialysis machine equipped with two blood pumps—one controlling arterial blood flow (Qb) and one controlling venous Qb. B. Braun has developed an innovative single‐pump SN HD system. Therefore, usability is improved by reducing complexity. The aim of this study was to compare dialysis parameters of the new single‐pump SN HD system with a double‐pump SN HD system available on the market (Fresenius Medical Care [FMC] 5008). In this two‐armed crossover study, patients were randomized into two groups (B. Braun ‐ FMC/FMC ‐ B. Braun). Study period was 2 weeks (6 HD sessions) for each SN HD system. Both B. Braun and FMC dialysis machines were operated in the single‐needle auto mode. With the FMC dialysis machines, Qb was optimized manually, whereas for B. Braun machines it was optimized automatically using the auto‐mode functionality. A phase volume of 25 mL, treatment time, needle type and size, and dialyzer type and size were kept constant per patient throughout the study. Due to technical prerequisites in the SN mode, online dialysis adequacy (Kt/V: K ‐ dialyzer clearance of urea; t ‐ dialysis time; V ‐ volume of distribution of urea) monitoring could only be performed in the B. Braun group. Twelve HD patients (5 male/7 female, mean age 75.5 ± 8.8 years, mean time on dialysis 4.97 ± 3.86 years, 3× weekly HD) were enrolled. Total number of treatments performed: n = 132 (65 B. Braun, 67 FMC) and the mean online Kt/V value in the B. Braun group was 1.26 ± 0.29 (n = 63). Mean dialysis time per session: B. Braun 253.4 ± 19.9 min, FMC 251.6 ± 18.8 min. Mean phase volume: B. Braun 25.1 ± 0.2 mL, FMC 25.4 ± 3.1 mL. Mean cumulated blood volume (CBV): B. Braun 55.0 ± 5.5 L, FMC 40.5 ± 5.9 L (P < 0.0001). Mean Qb: B. Braun 217.8 ± 12.9 mL/min, FMC 178.6 ± 14.9 mL/min (effective Qb) (P < 0.0001), which corresponds to a difference of 39.3 mL/min (22.0%). Higher Qb has an influence on the CBV. To evaluate this effect, CBV was corrected for the difference in Qb by calculating the CBV/Qb rate. The mean CBV/Qb rate was 252.2 ± 19.4 min (B. Braun) and 226.8 ± 27.6 min (FMC) (P < 0.0001) per session. This represents a highly significant difference of 11.4%. To support the in vivo data the dead time for opening/closure of the clamps of the FMC 5008 was measured, resulting in 364 milliseconds. Over a 240 min dialysis session, with a blood flow rate of 250 mL/min and a phase volume of 25 mL, it was estimated at about 14.56 min (6.1% of the session). Similarly, it was estimated that the dead time of the pumps of the FMC 5008 during 240 min dialysis session was 4.7 min (1.9% of the session). In case single needle therapy is the only practical option for a patient, the advantages of the new single‐pump single needle system—namely the proven higher cumulative blood volume, the alarm‐free auto‐regulation of the blood flow and the easier handling for the nursing staff—ensure higher treatment efficiency than conventional double‐pump single needle systems.
Introduction: Patients’ session-to-session variation has been shown to influence outcomes, making critical the monitoring of dialysis dose in each session. The aim of this study was to detect the intra-patient variability of blood single pool Kt/V as measured from pre-post dialysis blood urea and from the online tool Adimea®, which measures the ultraviolet absorbance of spent dialyzate. Methods: This open, one-armed, prospective non-interventional study, evaluates patients on bicarbonate hemodialysis or/and on hemodiafiltration. Dialysis was performed with B. Braun Dialog+ machines equipped with Adimea®. In the course of the prospective observation, online monitoring with Adimea® in each session was established without the target warning function being activated. A sample size of 97 patients was estimated. Results: A total of 120 patients were enrolled in six centers in China (mean age 51.5 ± 12.2 years, 86.7% males, 24.2% diabetics). All had an AV-fistula. The proportion of patients with blood Kt/V < 1.20 at baseline was 48.3%. During follow-up with Adimea®, the subgroup with Kt/V > 1.20 at baseline remains at the same adequacy level for more than 90% of the patients. Those with a Kt/V < 1.20 at baseline, showed a significant increase of Kt/V to 60% of the patients reaching the adequacy level >1.20. The coefficient of variation for spKt/V as evaluated by Adimea® was 9.6 ± 3.4%, not significantly different from the 9.6 ± 8.6% as blood Kt/V taken at the same time. Conclusion: Online monitoring of dialysis dose by Adimea® improves and maintains dialysis adequacy. Implementing online monitoring by Adimea into daily practice moves the quality of dialysis patient care a significant step forward.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.