A duplex real-time qPCR assay was developed for quantifying human nuclear and mitochondrial DNA in forensic samples. The nuclear portion of the assay utilized amplification of a ∼170-190 bp target sequence that spans the repeat region of the TH01 STR locus, and the mitochondrial portion of the assay utilized amplification of a 69 bp target sequence in the ND1 region. Validation studies, performed on an ABI 7000 SDS instrument using TaqMan R detection, demonstrated that both portions of the duplex assay provide suitable quantification sensitivity and precision down to 10-15 copies of each genome of interest and that neither portion shows cross-reactivity to commonly encountered non-human genomes. As part of the validation studies, a series of DNase-degraded samples were quantified using three different methods: the duplex nuclearmitochondrial qPCR assay, the ABI Quantifiler TM Human DNA Quantification Kit qPCR assay, which amplifies and detects a 62 bp nuclear target sequence, and slot blot hybridization. For non-degraded and moderately degraded samples in the series, all three methods were suitably accurate for quantifying nuclear DNA to achieve successful STR amplifications to yield complete profiles using the ABI AmpFlSTR R Identifiler TM kit. However, for highly degraded samples, the duplex qPCR assay provided better estimates of nuclear template for STR amplification than did either the commercial qPCR assay, which overestimated the quantity of STR-sized DNA fragments, leading to an increased proportion of undetected alleles at the larger STR loci, or slot blot hybridization, which underestimated the quantity of nuclear DNA, leading to an increased proportion of STR amplification artifacts due to amplification of excess template.
Robotic extraction of DNA from dilutions of blood and semen using either the BioRobots EZ1 or BioRobots M48 consistently produced lower recoveries than standard organic extractions of the same samples. In an effort to increase the efficiency of robotically extracted DNA, glycogen and carrier RNA were added following cell lysis. The addition of glycogen, postlysis, resulted in no improvement in DNA recovery with the BioRobot EZ1. However, when carrier RNA was added to the cell lysate of limited and degraded samples extracted on the EZ1 or the M48, DNA recoveries dramatically increased four- to 20-fold. DNA yields obtained by robotic extraction in the presence of carrier RNA were as high, or higher, as those obtained by organic extraction lacking carrier RNA, while experiments that utilized carrier RNA in both types of extractions showed increased sensitivity for both methods. Furthermore, carrier RNA substantially increased the recovery of fragmented DNA with the EZ1.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.