2006
DOI: 10.1111/j.1556-4029.2006.00204.x
|View full text |Cite
|
Sign up to set email alerts
|

Optimization of DNA Extraction from Low-Yield and Degraded Samples Using the BioRobotEZ1 and BioRobotM48

Abstract: Robotic extraction of DNA from dilutions of blood and semen using either the BioRobots EZ1 or BioRobots M48 consistently produced lower recoveries than standard organic extractions of the same samples. In an effort to increase the efficiency of robotically extracted DNA, glycogen and carrier RNA were added following cell lysis. The addition of glycogen, postlysis, resulted in no improvement in DNA recovery with the BioRobot EZ1. However, when carrier RNA was added to the cell lysate of limited and degraded sam… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

4
50
1

Year Published

2009
2009
2023
2023

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 110 publications
(55 citation statements)
references
References 14 publications
4
50
1
Order By: Relevance
“…The addition of poly(A) carrier RNA but not glycogen previously increased the recovery of automated silica-based extractions (BioRobots EZ1 and BioRobots M48, Qiagen) by an average of 24% (23). In another paper, a five-fold increased recovery was obtained in DNA extractions carried out on silica-based monoliths within a microfluidic device when poly(A) carrier RNA was added to the chaotropic salt solution (22).…”
Section: Discussionmentioning
confidence: 75%
“…The addition of poly(A) carrier RNA but not glycogen previously increased the recovery of automated silica-based extractions (BioRobots EZ1 and BioRobots M48, Qiagen) by an average of 24% (23). In another paper, a five-fold increased recovery was obtained in DNA extractions carried out on silica-based monoliths within a microfluidic device when poly(A) carrier RNA was added to the chaotropic salt solution (22).…”
Section: Discussionmentioning
confidence: 75%
“…First successful applications of the EZ1 system, which requires considerable less handson time of technical laboratory assistants than tradition column-based extraction systems [23], were published in the fi elds of microbiology [24] and forensic medicine [25,26] as early as in 2005. The EZ1 system was shown to be useful for the isolation of target DNA in low quantities, e.g., of fetal DNA in maternal plasma [21], or of DNA in partially degraded biological specimens [22]. Successful EZ1-based DNA extraction from formalin-fi xed, paraffi nembedded tissue samples [9], or otherwise long-term preserved tissue specimens [8] has been demonstrated.…”
Section: Discussionmentioning
confidence: 99%
“…DNA was isolated by two methods: a) Lysis Solution Extraction (LSE) [4]: samples were extracted using a 30 min incubation with 0.05% SDS and proteinase K at 56 C, followed by incubation at 100 C for 10 min. Concentration of the extract and removal of the SDS was accomplished through centrifugation (Amicon1 100 column, Millipore) pretreated with 1ng of Poly A RNA and b) QIAmp1 DNA Investigator1 Kit (Qiagen), according to the manufacturer's instruction.…”
Section: Dna Extractionmentioning
confidence: 99%