Colorectal cancer is the second most common cancer in Europe, and accurate lymph node staging in rectal cancer patients is essential for the selection of their treatment. MRI lymph node staging is complex, and few studies have been published regarding its reproducibility. This study assesses the inter- and intraobserver variability in lymph node size, apparent diffusion coefficient (ADC) measurements, and morphological characterization among inexperienced and experienced radiologists. Four radiologists with different levels of experience in MRI rectal cancer staging analyzed 36 MRI scans of 36 patients with rectal adenocarcinoma. Inter- and intraobserver variation was calculated using interclass correlation coefficients and Cohens-kappa statistics, respectively. Inter- and intraobserver agreement for the length and width measurements was good to excellent, and for that of ADC it was fair to good. Interobserver agreement for the assessment of irregular border was moderate, heterogeneous signal was fair, round shape was fair to moderate, and extramesorectal lymph node location was moderate to almost perfect. Intraobserver agreement for the assessment of irregular border was fair to substantial, heterogeneous signal was fair to moderate, round shape was fair to moderate, and extramesorectal lymph node location was substantial to almost perfect. Our data indicate that subjective variables such as morphological characteristics are less reproducible than numerical variables, regardless of the level of experience of the observers.
Background Ultrasound-guided percutaneous kidney tumor biopsy (UGPKB) plays an important role in the diagnosis of renal tumor but there are no consensuses with respect to the length and the extend of the post-biopsy observation period. Purpose To assess the short-term complication rate after UGPKB and to evaluate whether the onset of complications allows for the procedure to be performed in an outpatient setting with same-day discharge. Material and Methods Between March 2012 and March 2014, a total of 287 UGPKB were performed in an outpatient setting at a Danish university referral center. All patient records were retrospectively reviewed and post-biopsy complications as well as biochemical parameters were registered. Results The overall complication rate was 3.8% (11 patients). Major complications occurred in 1.0% of all cases (three patients); one patient with ongoing bleeding that required intervention and two patients with septicemia. Minor complications occurred in 2.8% of cases (eight patients); six patients with self-limiting gross hematuria, one patient with small asymptomatic subcapsular hematoma, and one patient with vasovagal syncope. The timing of both minor and major complication onset ranged from the time of biopsy and up to four days after discharge. Conclusion UGPKB of indeterminate renal masses in adult patients in an outpatient setting appears to be a safe procedure with a very low rate of major complications. Same-day discharge after renal mass biopsy seems feasible.
Background: Rectal cancer is a common malignancy. Since the introduction of bowel-screening programs, the number of patients with advanced adenomas and early rectal cancer has increased. Despite improved diagnostics, the discrimination between rectal adenomas and early rectal cancer (i.e., pT1–T2) remains challenging. The purpose of this systematic review was to evaluate the diagnostic performance of endorectal ultrasound (ERUS) elastography in discriminating rectal adenomas from cancer. Method: Using PRISMA guidelines, a systematic search was performed on PubMed, Embase, and MEDLINE databases. Studies evaluating the primary staging of rectal adenomas and cancer using ERUS elastography were included. Results: Six studies were identified; three evaluated the discrimination between adenomas and cancer; two evaluated adenomas and early rectal cancer (i.e., pT1–T2); one evaluated performance on different T categories. All studies reported increased diagnostic accuracy of ERUS elastography compared to ERUS. Sensitivity, specificity and accuracy ranged 0.93–1.00, 0.83–1.00 and 0.91–1.00, respectively, when discriminating adenomas from cancer. In the differentiation between adenomas and early rectal cancer, the sensitivity, specificity and accuracy were 0.82–1.00, 0.86–1.00 and 0.84–1.00, respectively. Conclusion: Elastography increases the accuracy of ERUS and may provide valuable information on malignant transformation of rectal lesions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.