Purpose The aim of this in vitro study was to compare the accuracy of different implant impression techniques of the maxillary full arch with tilted implants of two connection types. Materials and Methods Two maxillary edentulous acrylic resin models with two different implant connections (internal or external) served as a reference model. Each model had two anterior straight and two posterior angulated implants. Ninety impressions were made using an intraoral scanner (Trios 3Shape) with scan bodies for digital impression (groups DII and DIE), a custom open tray with additional silicone for the conventional direct group (groups CDI and CDE), and a custom closed tray with additional silicone for the conventional indirect group (groups CII and CIE) from both internal and external models, respectively. A coordinate-measuring machine (CMM) was used to measure linear and angular displacement for conventional specimens. For digital groups, an optical CMM was used to scan the reference model. STL data sets from the digital specimen were superimposed on STL reference data sets to assess angular and linear deviations. Data were analyzed with three-way ANOVA and t-test at α=0.05. Results There were significant angular and linear distortion differences among three impression groups (P < 0.001), angular distortion differences between internal and external connections (P < 0.001), and between straight and tilted implants for either linear (P < 0.001) or angular (P=0.002) distortion. The type of the connection and implant angle did not have any effect on linear and angular distortion of the digital technique (p > 0.05). Minimum angular and linear distortion was seen for tilted implants in DII and DIE groups (0.36° ± 0.37 and 0.16 ± 0.1 mm). Conclusion Impression techniques (digital versus conventional) affected the transfer accuracy. Digital techniques demonstrated superior outcome in comparison with conventional methods, and the direct technique was better than the indirect conventional technique. Connection type and implant angulation were other factors that influenced accuracy. However, when digital impression was applied, accuracy was not affected by the type of connection and angulation.
According to the results of this study, the digital implant impression technique had the least accuracy. Based on the study outcomes, distance and angulation errors associated with the intraoral digital implant impressions were too large to fabricate well-fitting restorations for partially edentulous patients. The pick-up implant impression technique was the most accurate, and the transfer technique revealed comparable accuracy to it.
The impression coping shape had more impact on impression inaccuracy than impression technique did. Understanding of the magnitude and variability of distortion when employing certain impression-making methods and impression coping shapes helps the clinician to select a better implant component and impression technique.
Discoloration of teeth undergoing REPs is an unfavorable outcome. Considering the significant contribution of TAP containing minocycline to the coronal tooth discoloration even after sealing the pulp chamber walls, the revision of current guidelines in relation to the use of TAP with minocycline might need to be revised.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.