BackgroundOcular trauma is an important cause of visual loss worldwide. Improvements in our knowledge of the pathophysiology and management of ocular trauma during the past 30 years, in conjunction with advances in the instrumentation and techniques of ocular surgery, have improved the efficacy of vitreoretinal surgery in injured eyes. The aim of the current study was to determine the visual outcomes and prognostic factors of open-globe injuries in the Japanese population.MethodsRetrospective study of 59 eyes of 59 patients presented with open globe injuries between September 2008 and March 2014 at Nagasaki University Hospital was conducted.Demographic factors including age, gender, and clinical data such as cause of injury, presenting visual acuity (VA), location of injury, type of injury, lens status, presence of intraocular foreign body, types of required surgeries, and final VA were recorded. According to the classification of Ocular Trauma Classification Group, wound location was classified into three zones. Chi-square test was used to compare presented data.ResultsOut of the 59 patients, 46 were placed in the Light Perception (LP) group, and 13 were placed in the No Light Perception (NLP) group. Work-related trauma was the most common cause (27 eyes) followed by falls (19eyes). Work-related trauma was common in males (P = 0.004), while falls was significantly common in females (P = 0.00001). Zone III injuries had statistically significantly poor prognostic factor compared to other zones (P = 0.04). All cases of NLP group (100%) presented with rupture globe. Poor VA at first visit (P = 0.00001), rupture globe (P = 0.026), history of penetrating keratoplasty (PK) (P = 0.017), retinal detachment (RD) (P = 0.0001), vitreous hemorrhage (VH) (P = 0.044), and dislocation of crystalline lens (P = 0.0003) were considered as poor prognostic factors.ConclusionPoor VA at first visit, rupture globe, zone III injuries, history of penetrating keratoplasty, RD, VH, and dislocation of crystalline lens were found to be poor prognostic factors. PPV had a good prognostic value in open globe injuries associated with posterior segment involvement.
Objective: Acute corneal permeability change after instillation of benzalkonium chloride (BAC) was evaluated using a newly developed in vivo corneal transepithelial electric resistance (TER) measurement method. Method: Corneal TER was measured by Ag/AgCl electrodes placed in the anterior aqueous chamber and on the cornea of live rabbit eyes. TER was measured and TER change after instillation of 0.05% BAC solution was monitored. After TER measurement, cornea was excised and fixed for transmission and scanning electron microscopy. For the control study, physiologic saline was used instead of BAC. Results: The TER of normal rabbit cornea was 602.3 ± 195.0 Ωcm2. TER decreased instantly after instillation of 0.05% BAC. In 5 s, TER decreased to 58.3 ± 5.2%. In 60 s, TER decreased to 18.5 ± 3.2%. At all time points, TER after instillation of 0.05% BAC was significantly lower than that of the control (p < 0.0001). Dissociation of tight junctions and the destruction of superficial cell membranes were observed under electron microscopy. Conclusion: Corneal epithelial change with increased permeability is rapid and intense after the instillation of highly concentrated BAC solution, accompanied by disorder of tight junctions and cell membranes of superficial cells. The newly developed in vivo corneal TER measurement method is suitable for assessing acute corneal change after drug instillation.
Instillation with BAC immediately disrupted the corneal epithelium. Corneal epithelial cell death is supposed to be associated with a decline in barrier function; thus, corneal TER measurement in vivo can assess the acute toxicity of preservatives added to ophthalmic drugs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.