This study investigates whether in-room computed tomography (CT)-based adaptive treatment planning (ATP) is robust against interfractional location variations, namely, interfractional organ motions and/or applicator displacements, in 3D intracavitary brachytherapy (ICBT) for uterine cervical cancer. In ATP, the radiation treatment plans, which have been designed based on planning CT images (and/or MR images) acquired just before the treatments, are adaptively applied for each fraction, taking into account the interfractional location variations. 2D and 3D plans with ATP for 14 patients were simulated for 56 fractions at a prescribed dose of 600 cGy per fraction. The standard deviations (SDs) of location displacements (interfractional location variations) of the target and organs at risk (OARs) with 3D ATP were significantly smaller than those with 2D ATP (P < 0.05). The homogeneity index (HI), conformity index (CI) and tumor control probability (TCP) in 3D ATP were significantly higher for high-risk clinical target volumes than those in 2D ATP. The SDs of the HI, CI, TCP, bladder and rectum D2cc, and the bladder and rectum normal tissue complication probability (NTCP) in 3D ATP were significantly smaller than those in 2D ATP. The results of this study suggest that the interfractional location variations give smaller impacts on the planning evaluation indices in 3D ATP than in 2D ATP. Therefore, the 3D plans with ATP are expected to be robust against interfractional location variations in each treatment fraction.
In this study, we proposed and evaluated position correction accuracy assessment method with a phantom for IGRT system with add-on six-degrees-of-freedom radiotherapy (6D) couches in couch rotation. Methods and Materials: A phantom was used in a self-build phantom. We were scanned with computed tomography (CT) for radiotherapy planning and planned treatment isocenter to fall in line with CT center by treatment planning system. At first, we examined data of CT slice thickness for digitally reconstructed radiograph of QA phantom. Next, we measured uncertainty for IGRT system. We performed position correction accuracy for IGRT system with QA phantom and digital angle meter. Results: Detection and correction errors for pitch and roll direction were within 0.3 degree in all verifications. Conclusions: We proposed a quality control method for position correction accuracy of 6D couch. The method was able to evaluate the accuracy of detection and correction of 6D couch and revealed the deviation of the origin of the couch rotation.
A nationwide survey was conducted in Japan on paediatric CT among children of public health and school nurses to examine a possibility for a follow-up study on radiation effects. A survey questionnaire was sent out to 3173 public primary and junior high schools and 317 public health centres during October to December in 2009. According to the collected responses, 410 (16.2 %) children received the CT scans and the total number of CT scans was 585. Most of respondents expressed a high interest in radiation health effects and an intent to participate in the epidemiological study that will follow-up the health conditions of children. This study provides information to discuss the feasibility of the epidemiological study on health effects in children who received CT scans.
The purpose was to study comparative evaluation of calculated dose distribution by X-ray Voxel Monte Carlo (XVMC) for dose calculation in Acuros XB (AXB). The dose commissioning and head and neck volumetric modulated arc therapy (VMAT) clinical cases were compared for AXB in Eclipse and XVMC in Monaco. Methods: For TrueBeam at 6 MV, we compared the dose commissioning for simple rectangle, heterogeneity correction, and multileaf collimator (MLC) characteristics. 15 clinical cases were compared for computation times, calculation accuracy, dose-volume histogram (DVH), and 3D-γ analysis (γ 3%/2 mm). Results: There was no difference between the calculated values of jaw field, the measurement errors of both were within± 1%, and the dose profiles of water, bone, and lung equivalent slab phantoms were in good agreement. There was no difference in transmission, tongue and groove effect, and there was a difference of less than 10% in leaf-end transmission. In clinical cases, the computation time of XVMC was a half time that of AXB, the average values of the dose difference between the two dose calculations were -1.17±2.14%, and there was no difference in measurement error (AXB: -0.73±0.79%, XVMC: -0.07±1.21%). In DVH, max doses of XVMC were about 3% higher in planning target volume (PTV) and gross tumor volume (GTV), but the pass rate of 3D-γ analysis was overall 95.11±2.59%, which was in good agreement. Conclusions: Both dose calculation algorithms were equivalent, suggesting that Monaco XVMC is a verification method with a high accuracy for comparative evaluation of calculated dose distribution.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.