Japanese patients in this study showed a relatively low prevalence of chronic cluster headaches, and uncoupling of a sense of restlessness and restless behaviour. These features of cluster headache may be more common in Japanese and Taiwanese patients than in Caucasian patients.
The blood flow velocity and diameter of feline pial arteries, ranging in diameter from 20 to 200 microns, were measured simultaneously using a newly developed video camera method under steady-state conditions for all other parameters. There was a linear relationship between blood flow velocity and pial artery diameter (y = 0.340x + 0.309), the correlation coefficient being 0.785 (p less than 0.001). The average values for blood flow velocity in pial arteries less than 50 microns, greater than or equal to 50 but less than 100 microns, greater than or equal to 100 but less than 150 microns, and greater than or equal to 150 microns in diameter were 12.9 +/- 1.3, 24.6 +/- 3.4, 42.1 +/- 4.7, and 59.9 +/- 5.3 mm/s, respectively. Blood flow rate was calculated as a product of the cross-sectional area and the flow velocity. The blood flow rate increased exponentially as the pial artery diameter increased (y = 2.71 X 10(-4) x2.98). The average values for blood flow rate in pial arteries less than 50 microns, greater than or equal to 50 but less than 100 microns, greater than or equal to 100 but less than 150 microns and greater than or equal to 150 microns in diameter were 12.8 +/- 1.5, 122.1 +/- 24.8, 510.2 +/- 74.8, and 1524.2 +/- 174.4 10(-3) mm3/s, respectively. Hemorheological parameters such as the wall shear rate and Reynolds' number were also calculated. The data obtained provide a useful basis for further investigations in the field of cerebral circulation.
Methods are described for non-invasive, computer-assisted serial scanning throughout the human brain during eight minutes of inhalation of 27%-30% Xenon gas in order to measure local cerebral blood flow (LCBF). Optimized Xenon-enhanced computed tomography (XeCT) was achieved by 5-second scanning at one-minute intervals utilizing a state-of-the-art CT scanner and rapid delivery of Xenon gas via a face mask. Values for local brain-blood partition coefficients (L lambda) measured in vivo were utilized to calculate LCBF values. Previous methods assumed L lambda values to be normal, introducing the risk of systematic errors, because L lambda values differ throughout normal brain and may be altered by disease. Color-coded maps of L lambda and LCBF values were formatted directly onto CT images for exact correlation of function with anatomic and pathologic observations (spatial resolution: 26.5 cubic mm). Results were compared among eight normal volunteers, aged between 50 and 88 years. Mean cortical gray matter blood flow was 46.3 +/- 7.7, for subcortical gray matter was 50.3 +/- 13.2 and for white matter was 18.8 +/- 3.2. Modern CT scanners provide stability, improved signal to noise ratio and minimal radiation scatter. Combining these advantages with rapid Xenon saturation of the blood provides correlations of L lambda and LCBF with images of normal and abnormal brain in a safe, useful and non-invasive manner.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.