AimComputer-aided diagnosis (CAD) software for bone scintigrams have recently been introduced as a clinical quality assurance tool. The purpose of this study was to compare the diagnostic accuracy of two CAD systems, one based on a European and one on a Japanese training database, in a group of bone scans from Japanese patients.MethodThe two CAD software are trained to interpret bone scans using training databases consisting of bone scans with the desired interpretation, metastatic disease or not. One software was trained using 795 bone scans from European patients and the other with 904 bone scans from Japanese patients. The two CAD softwares were evaluated using the same group of 257 Japanese patients, who underwent bone scintigraphy because of suspected metastases of malignant tumors in 2009. The final diagnostic results made by clinicians were used as gold standard.ResultsThe Japanese CAD software showed a higher specificity and accuracy compared to the European CAD software [81 vs. 57 % (p < 0.05) and 82 vs. 61 % (p < 0.05), respectively]. The sensitivity was 90 % for the Japanese CAD software and 83 % for the European CAD software (n.s).ConclusionThe CAD software trained with a Japanese database showed significantly higher performance than the corresponding CAD software trained with a European database for the analysis of bone scans from Japanese patients. These results could at least partly be caused by the physical differences between Japanese and European patients resulting in less influence of attenuation in Japanese patients and possible different judgement of count intensities of hot spots.
Our objective was to clarify intracranial cerebrospinal fluid (CSF) flow dynamics in normalpressure hydrocephalus (NPH). Frequency analyses of CSF flow measured with phase-contrast cine MRI were performed. The CSF flow spectra in the aqueduct were determined in patients (n=51) with NPH, brain atrophy or asymptomatic ventricular dilation (VD), and in healthy volunteers (control group; n=25). The changes in CSF flow spectra were also analyzed after intravenous injection of acetazolamide. Moreover, a phase transfer function (PTF) calculated from the spectra of the driving vascular pulsation and CSF flow in the aqueduct were assessed. These values were compared with the pressure volume response (PVR). The amplitude in the NPH group was significantly larger than that in the VD or control group because of a decrease in compliance. The phase in the NPH group was significantly different from that in either the VD or the control group, but no differ-ence was found between the VD and control groups. The amplitude increased in all groups after acetazolamide injection. The PTF in the NPH group was significantly larger than in the control group, and a positive correlation was noted between PTF and PVR. Frequency analyses of CSF flow measured by cine MRI make it possible to noninvasively obtain a more detailed picture of the pathophysiology of NPH.
The aim of this study was to demonstrate the usefulness of SwiftScan with a low-energy high-resolution and sensitivity (LEHRS) collimator for bone scintigraphy using a novel bone phantom simulating the human body. SwiftScan planar image of lateral view was acquired in clinical condition; thereafter, each planar image of different blend ratio (0–80%) of Crality 2D processing were created. SwiftScan planar images with reduced acquisition time by 25–75% were created by Poisson’s resampling processing. SwiftScan single photon emission computed tomography (SPECT) was acquired with step-and-shoot and continuous mode, and SPECT images were reconstructed using a three-dimensional ordered subset expectation maximization incorporating attenuation, scatter and spatial resolution corrections. SwiftScan planar image showed a high contrast to noise ratio (CNR) and low percent of the coefficient of variance (%CV) compared with conventional planar image. The CNR of the tumor parts in SwiftScan SPECT was higher than that of the conventional SPECT image of step and shoot acquisition, while the %CV showed the lowest value in all systems. In conclusion, SwiftScan planar and SPECT images were able to reduce the image noise compared with planar and SPECT image with a low-energy high-resolution collimator, so that SwiftScan planar and SPECT images could be obtained a high CNR. Furthermore, the SwiftScan planar image was able to reduce the acquisition time by 25% when the blend ratio of Clarity 2D processing set to more than 40%.
IQ·SPECT (Siemens Medical Solutions) is a solution for high-sensitivity and short-time acquisition imaging of the heart for a variable angle general purpose gamma camera. It consists of a multi-focal collimator, a cardio-centric orbit and advanced iterative reconstruction, modeling the image formation physics accurately. The multi-focal collimator enables distance-dependent enlargement of the center region while avoiding truncation at the edges. With the specified configuration and a cardio-centric orbit it can obtain a fourfold sensitivity increase for the heart at the center of the scan orbit. Since IQ·SPECT shows characteristic distribution patterns in the myocardium, appropriate acquisition and processing conditions are required, and normal databases are convenient for quantification of both normal and abnormal perfusion images. The use of prone imaging can be a good option when X-ray computed tomography (CT) is not available for attenuation correction. CT-based attenuation correction changes count distribution significantly in the inferior wall and around the apex, hence image interpretation training and additional use of normal databases are recommended. Recent reports regarding its technology, Japanese Society of Nuclear Medicine working group activities, and clinical studies using 201Tl and 99mTc-perfusion tracers in Japan are summarized.
Objective: To evaluate the advantage of upright position imaging with a medium-energy collimator for the detection of sentinel lymph node (SLN). Methods: Thirty-four patients with operable breast cancer underwent sentinel node lymphoscintigraphy with 99m Tc-tin colloid. Images were obtained in 5 different positions and paired images from the same patient were compared using side-by-side interpretation. Images were compared in 3 groups: group 1 (anterior view); supine (SAV) vs. upright (UAV), group 2 (oblique view); supine (SOV) vs. upright (UOV), and group 3 (oblique view); modified supine (MOV) vs. UOV. Image quality was evaluated using a 3-grade scale of clear, faint, and equivocal depiction, and correlated to 3 parameters: distance from injection site to lymph node (hot node), counts in hot node, and image contrast. Parameters in group 1 were compared by classifying the primary tumor site into 4 subregions. Results: Image quality in all 3 groups was more enhanced on the image obtained in the upright position than that in the supine position. Obtaining images in an upright position increased the mean distances by 1.5-3.2 cm, and mean contrasts were significantly increased by 0.13-0.31 (p < 0.05). It was shown that image quality was more greatly affected by image contrast than by counts in the hot node. Image contrast of 0.5 seemed an appropriate threshold level for detection of the hot node. On comparison of tumor sites, the upper outer quadrant (C) region of the 4 subregions demonstrated greater contrast enhancement on upright position images. Conclusion: Clinical images obtained in an upright position with a mediumenergy collimator were superior to those obtained in a supine position. Use of this procedure is recommended to enhance lymph node detection on sentinel node lymphoscintigraphy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.