This manuscript elucidates the mechanisms responsible for aging-induced reduction in lead leaching from scrubber residues. Leaching tests (JLT13) were conducted on 48 types of scrubber residues and lead solubility was found to be significantly reduced independent of incinerator type or type of gas treatment method. Reaction kinetics that result in lead solubility reduction were shown to be proportional to carbon dioxide partial pressure and in many cases were limited by mass transfer to the residue. With forced gas convection through the residue and a CO2 partial pressure of 0.3%, the concentration of lead in leachate was reduced from 84 mg L(-1) to < 0.5 mg L(-1) in two days. Ettringite analogs (Ca6Al2 (SO4) 3(OH)2 . 26H2O) were identified by X-Ray Diffraction in the wetted scrubber residues early in the aging process; these appear to have been converted into gypsum (CaSO4 . 2H2O) and vaterite (CaCO3) in the aged material. All of these solid phases are believed to substitute lead into their crystal structure and evidence for this attenuation mechanism is presented.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.