A presence of a strong external magnetic field can affect a flow distribution of a liquid-metal (LM) coolant in a fusion blanket, due to magnetohydrodynamic (MHD) effects. LM blankets have some manifolds, where the coolant flow from a single supply channel is distributed to multiple parallel channels. Since these manifolds have complex geometries, an interaction between induced axial electric currents and the magnetic field reorganizes the flow to be three-dimensional. A flow imbalance in such a complicated manifold affects heat removal performances, which is closely related to the blanket feasibility and safety. This study was performed to experimentally and numerically investigate a LM distribution in MHD flows in an electrically insulating manifold with changing the intensity and orientation of the magnetic field transverse to the flows. The flow passage employed in this study is a U-turn manifold consisting of an upward rectangular duct, a U-turn branching area, and two downward ducts with insulating walls. The gallium-indium-tin eutectic alloy (GaInSn) was employed as a working fluid. The present study shows that, as the magnetic field is applied more perpendicularly with respect to the U-turn, much amount of the fluid flows in the inner downward channel than that in the outer one.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.