We present 2 cases of severe re-expansion pulmonary edema (RPE) after one-lung ventilation (OLV) for thoracic surgery. A 32-y-old woman with multiple lung metastases developed severe RPE after OLV during lung resection surgery. A 37-y-old man with infective endocarditis also developed severe RPE after OLV for mitral valve plasty with minimally invasive cardiac surgery. In both cases, results of a preoperative pulmonary function test and oxygenation were almost normal, and pleural effusion or pulmonary congestion was not detected in preoperative computed tomography; however, there was a possibility that subclinical lung injury existed before surgery. The levels of interleukin-8 and monocyte chemotactic protein-1, which are thought to play important roles in the development of lung injury, in bronchial secretions were extremely high after the onset of RPE. These results suggest that the pathogenesis of RPE shares, at least in part, a common pathophysiology of acute lung injury. Key words: pulmonary edema; one-lung ventilation; interleukin-8; monocyte chemotactic protein-1. [Respir Care 2015;60(8):e134 -e140.
Although the accuracy of the SCGM system was clinically acceptable in the perioperative period, sensor accuracy was affected by CPB and showed lower glucose levels.
A patient with congenital insensitivity to pain with anhidrosis (CIPA) underwent revision of total hip arthroplasty under general anesthesia with only propofol. During surgery, neither elevation of stress hormones nor hemodynamic changes associated with pain occurred; however, when blood was rapidly lost, compensatory tachycardia was observed. Although patients with CIPA are complicated with autonomic disturbance due to dysfunction of postganglionic sympathetic fibers, this compensatory response indicated that the adrenal glands in patients with CIPA secrete catecholamine as part of a compensatory response during bleeding under general anesthesia.
Intraoperative massive bleeding is associated with high rates of mortality and anesthetic management of massive bleeding is challenging because it is necessary to achieve volume resuscitation and electrolyte correction simultaneously during massive transfusion. We report a case of life-threatening bleeding of more than 80,000 mL during liver transplantation in which real-time QTc monitoring was useful for an extremely large amount of calcium administration for treatment of hypocalcemia. A 47-year-old female with a giant liver due to polycystic liver disease was scheduled to undergo liver transplantation. During surgery, life-threatening massive bleeding occurred. The maximum rate of blood loss was approximately 15,000 mL/hr and the total amount of estimated blood loss was 81,600 mL. It was extremely difficult to maintain blood pressure and a risk of cardiac arrest continued due to hypotension. In addition, even though administration of insulin and calcium was performed, electrolyte disturbances of hyperkalemia and hypocalcemia with prolongation of QTc interval occurred. At that time, we visually noticed that the QT interval was shortened in response to bolus calcium administration, and we used the change of real-time QTc interval as a supportive indicator for calcium correction. This monitoring allowed for us to administer calcium at an unusually high rate, by which progression of hypocalcemia was prevented. Levels of hemoglobin and coagulation factors were preserved both by restriction of crystalloid infusion and by a massive transfusion protocol. The patient was extubated without pulmonary edema or cardiac overload and was finally discharged without any sequelae. Intensive and cooperative management for massive transfusion and electrolyte correction using QTc monitoring was considered to be a key for successful management.
Background
Anaphylaxis caused by a catheter itself used for endovascular surgery is rare, and a method for detection of a causative catheter has not been established. We report a case of catheter-induced anaphylaxis in which the causative catheter was successfully detected.
Case presentation
A 47-year-old male underwent neuroendovascular surgery. During surgery, blood pressure suddenly dropped and the level of tryptase indicated the occurrence of anaphylaxis. There were 24 candidate agents for the cause of anaphylaxis including 8 catheters. We performed the basophil activation test by directly mixing the catheter with blood. One catheter coated with a hyaluronic acid product showed a positive reaction, and we confirmed the result by a modified skin test using an elution solution of the catheter. Later, we successfully completed the neuroendovascular surgery without the catheter.
Conclusions
The methods used in this case can be useful for the detection of the causative agent in catheter-induced anaphylaxis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.