Aims Implantable cardiac monitors (ICMs) can generate false-positive (FP) alerts. Although these devices have an extended programmability, there are no recommendations on their optimization to reduce not-relevant activations. We tested a strategic programming optimization guide based on the type of FP and investigated the safety and feasibility of the nurse-led insertion of ICMs with a long-sensing vector. Methods and Results Consecutive patients implanted by trained nurses with long-sensing vector ICM were enrolled in a one-month observational stage (Phase A). Patients who had ≥10 FP episodes underwent ICM reprogramming based on the predefined guide and were followed for an additional month (Phase B). A total of 78 patients had successful ICM insertion by nurses with a mean R wave amplitude of 0.96 ± 0.43 mV and an 86% P wave visibility. Only one patient reported a significant device-related issue, and nurse-delivered ICM was generally well accepted by the patients. During phase A, 11 patients (14%) generated most of FP (3,627/3,849; 94%) and underwent ICM reprogramming. In the following month (Phase B), 5 patients (45%) were free from FP and 6 (55%) transmitted 57 FP alerts (98% reduction compared with Phase A). The median number of FP per patient was significantly reduced after reprogramming (195 [interquartile range, 50-311] versus 1 [0-10], p = 0.0002). Conclusion A strategic reprogramming of ICM in those patients with a high FP alert burden reduces the volume of erroneous activations with potential benefits for the remote monitoring service. No concerns were raised regarding nurse-led insertion of ICMs with a long-sensing vector.
Aims Current guidelines recommend remote follow-up for all patients with cardiac implantable electronic devices. However, the introduction of a remote follow-up service requires specifically dedicated organization. We evaluated the impact of adopting remote follow-up on the organization of a clinic and we measured healthcare resource utilization. Methods In 2016, we started the implementation of the remote follow-up service. Each patient was assigned to an experienced nurse and a doctor in charge with preestablished tasks and responsibilities. During 2016 and 2017, all patients on active follow-up at our center were included in the service; since 2018, the service has been fully operational for all patients following postimplantation hospital discharge. Results As of December 2018, 2024 patients were on active follow-up at the center. Of these, 93% of patients were remotely monitored according to the established protocol. The transmission rates were: 5.3/patient-year for pacemakers, 6.0/patient-year for defibrillators, and 14.1/patient-year for loop recorders. Only 21% of transmissions were submitted to the physician for further clinical evaluation, and 3% of transmissions necessitated an unplanned in-hospital visit for further assessment. Clinical events of any type were detected in 39% of transmissions. Overall, the nurses’ total workload was 3596 h per year, that is, 1.95 full-time equivalent, which resulted in 1038 patients/nurse. The total workload for physicians was 526 h per year, that is, 0.29 full-time equivalent. After 1 year on follow-up, most patients judged the service positively and expressed their preference for the new follow-up approach. Conclusion A remote follow-up service can be implemented and efficiently managed by nursing staff with minimal physician support. Patients are followed up with greater continuity and seem to appreciate the service.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.