Objective: To evaluate a fully automated processing system (TACAS™ Pro) for liquid-based procedures (LBPs). Methods and Materials: Materials were 3,483 and additionally 502 specimens that were taken at Kanagawa Health Service Association. Specimens obtained with a Cervex-Brush® were first smeared to glass slides using one side of the brush and then processed to TACAS Pro. Results: (1) The microscopy watching time per normal case was 3.65 ± 0.85 min in the conventional procedure, whereas in the LBP it was 1.95 ± 0.60 min, and the latter reduced workload to 53%. (2) The handling time of TACAS Pro per day was 2 h and 25.8 min. The workload at a laboratory offset it and revealed the work saving to be 63.8%. (3) Unsatisfactory rates were 0% in the conventional procedure, whereas in the LBP it was 1.88% at first. The latter rate decreased to 0.5% after system improvement. (4) Specimens which may disturb microscopy analysis were found in 1.06%, including 3 cases of possible carry-over of cells to the following slides. An additional study with the revised system confirmed no carry-over. (5) Incidences of abnormal cytology were consistent between the two methods. Conclusions: The revised automated processing system TACAS Pro is a feasible and useful LBP and reduces the workload of cytology laboratories.
Objective: To find an appropriate sampling device for a liquid-based procedure in the population screening for cervical cancer, focusing on bleeding at sampling and the amount of cells smeared. Methods and Materials: 1,000 consecutive women who underwent primary screening were studied. The specimens were obtained with the cotton stick/Cytobrush® method in the first 500 cases or with the Cervex-Brush® in the following 500 subjects, and were processed using the Thinlayer Advanced Cytology Assay System (TACAS™) following the manufacturer’s instructions. Results: (1) Bleeding at cellular sampling using the cotton stick/Cytobrush and Cervex-Brush methods occurred in 1.2 and 8.8% of the cases, respectively (p < 0.0001). (2) The incidences of cells obtained with the two methods which covered the whole area, <1/2 and ≥1/4, and <1/4 of the observation fields were 55.4 versus 62.2% (p < 0.05), 14.6 versus 9.4% (p < 0.05), and 2.0 versus 4.0% (p < 0.05), respectively. (3) The incidences of endocervical or metaplastic cells obtained with ≥500 and <10 were 34.6 versus 20.0% (p < 0.01) and 9.4 versus 18.4% (p < 0.01), respectively. In cases of cells covering <1/4, incidences with <10 were 0 and 0.6% (n = 3), respectively. (4) Detection rates of abnormal cytology were 3.4 and 5.2% (n.s.), including atypical squamous cells of undetermined significance in 2.4 and 3.2%. Conclusions: The cotton stick/Cytobrush is superior to the Cervex-Brush as a cellular sampling device for the TACAS liquid-based procedure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.