The behaviour of a pile subjected to thermo-mechanical loads was studied in situ with the aim of quantifying the thermal influence on the bearing capacity of heat exchanger piles. To accomplish this, a pile situated in a building under construction was equipped with a pipe system to inject heat into it using a special heat pump. Load cells, deformation gauges, and thermometers were installed to evaluate the behaviour of the pile during seven tests with coupled thermo-mechanical loads. The temperature variations applied to the pile were of the order of 15°C and the mechanical load reached 1300 kN. The results permitted the quantification of three significant effects brought about by the temperature increase: (i) pile uplift, (ii) mobilization of skin friction due to the relative displacement of the pile with respect to the ground, (iii) additional load generated in the pile by constrained dilation.Key words: heat exchanger pile, in situ test, loading test, thermo-mechanical loads, mobilization of skin friction.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.