Background: Fractures of the distal femoral physis are the most common physeal fracture sustained by skeletally immature dogs. Reduction and stabilization of these fractures can sometimes be achieved through closed reduction, primarily in fractures that are nominally displaced. Circular external fixator constructs have been used to assist in indirect, closed reduction of fractures at other anatomic locations in dogs and this report describes application of this method to reduce a displaced Salter-Harris type II fracture of the distal femur in a 1-year-old dog.
Case Description: A 1-year-old female spayed Akita was referred for treatment of a Salter-Harris type II fracture of the right distal femur. The epiphyseal segment was laterally and slightly caudally displaced. Multiple attempts to manually reduce the fracture during surgery were unsuccessful, so a two-ring circular external fixator construct was applied to facilitate distraction and reduction. The construct was applied by placing a medial-to-lateral Kirschner wire in both the mid-femoral diaphysis and in the distal femoral epiphysis. Distraction of the construct provided sufficient separation of the fracture segments to facilitate near anatomic reduction. The fracture was stabilized with two percutaneously placed Steinmann pins placed in Rush fashion. Radiographic union was confirmed 5 weeks after surgery. The dog was not lame and was bearing more weight on the right pelvic limb, as assessed using force plate analysis, 9 months following surgery. Goniometric measurements of stifle range of motion and thigh muscle circumference were similar between the pelvic limbs.
Conclusion: Application of a two-ring circular construct would appear to be useful to facilitate closed reduction and percutaneous stabilization of distal femoral physeal fractures.
ObjectiveTo determine the accuracy of needle arthroscopy (NA) for the diagnosis of medial meniscal tears in dogs with cranial cruciate ligament rupture (CCLR).Study designProspective clinical trial.AnimalsTwenty‐six client‐owned dogs.MethodsDogs with CCLR and scheduled to undergo tibial plateau leveling osteotomy were recruited for the study. Needle arthroscopy was performed by an experienced surgeon; the same dog subsequently underwent standard arthroscopy (SA) by another experienced surgeon who was blinded to the NA findings. The SA arthroscopy findings were used as the gold standard. Arthroscopy time, visibility of the menisci, ability to probe the menisci, and the presence of meniscal tears were recorded for both arthroscopies. The degree of lameness before and after NA was subjectively quantified.ResultsThe sensitivity and specificity to diagnose medial meniscal tears with NA was 95% and 100%, respectively. Visibility of the menisci was lower (P < .01), probing of the lateral meniscus was harder (P = .0017), and procedure time was shorter (P = .073) with NA when compared to SA. The lameness scores did not differ before and after NA (P = .25).ConclusionNeedle arthroscopy could be performed rapidly with low morbidity, and had high accuracy for detecting medial meniscal tears in dogs with CCLR.Clinical significanceNeedle arthroscopy is a promising minimally invasive technique for diagnosing medial meniscal tears in dogs with CCLR.
ObjectiveThis article is a preliminary study to compare the ability of 0.05% chlorhexidine diacetate (CD) and 1% povidone‐iodine (PI) solutions to reduce bacterial contamination on the canine external ear canal during initial patient preparation and comparison of the incidence of immediate tissue reactions.Study designThe study is a multi‐institutional, randomised, clinical prospective study.Animals or sample populationDogs (n = 19) undergoing total ear canal ablation with bulla osteotomy (TECABO).MethodsThe external ear of each dog was cleaned with the assigned antiseptic solution. Culture of the ear was performed by standard techniques to semi‐quantitatively evaluate bacterial growth and to identify bacterial organisms pre‐ and post‐antiseptic use.ResultsBoth antiseptic groups showed a significant reduction in bacterial growth score (BGS) between pre‐ and post‐antiseptic use (CD p = 0.009, PI p = 0.005). There was no difference in the reduction of BGS between CD and PI solutions (p = 0.53). Minor adverse skin reactions occurred in 25% of cases. There was no significant difference in the occurrence of adverse skin reactions between antiseptics (p = 0.63).ConclusionCD and PI were similarly able to decrease the number of bacteria on the external ear following initial preparation. No difference in the incidence of adverse tissue reactions was found.Clinical significanceProperly diluted aqueous formulations of either antiseptic may be used for safe preparation limited to the external ear canal of dogs. Additional studies evaluating outcomes such as duration of bacterial inhibition and incidence of surgical site infections are needed to fully elucidate differences between CD and PI antiseptics prior to TECABO.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.