Summary Motor behaviors recruit task-specific neuronal ensembles in motor cortices, which are consolidated over subsequent learning. However, little is known about the molecules that can identify the participating neurons and predict the outcomes of the consolidation process. Using a mouse rotarod-learning task, we showed that lesion or inactivation of the secondary motor (M2) cortex disrupts learning of skilled movements. We tracked the endogenous promoter activity of the neuronal activity-regulated gene Arc in individual M2 neurons during rotarod learning by in vivo two-photon imaging of a knock-in reporter. We found that task training initially recruits Arc-promoter-activated neurons and then consolidates them into a specific ensemble exhibiting persistent reactivation of Arc-promoter. The intensity of a neuron’s initial Arc-promoter activation predicts its reactivation probability and neurons with weak initial Arc-promoter activation are dismissed from the ensemble during subsequent training. Our findings demonstrate a task-specific Arc-dependent cellular consolidation process in M2 cortex during motor learning.
The James Webb Space Telescope (JWST) is a large, infrared space telescope that has recently started its science program which will enable breakthroughs in astrophysics and planetary science. Notably, JWST will provide the very first observations of the earliest luminous objects in the universe and start a new era of exoplanet atmospheric characterization. This transformative science is enabled by a 6.6 m telescope that is passively cooled with a 5 layer sunshield. The primary mirror is comprised of 18 controllable, low areal density hexagonal segments, that were aligned and phased relative to each other in orbit using innovative image-based wave front sensing and control algorithms. This revolutionary telescope took more than two decades to develop with a widely distributed team across engineering disciplines. We present an overview of the telescope requirements, architecture, development, superb on-orbit performance, and lessons learned. JWST successfully demonstrates a segmented aperture space telescope and establishes a path to building even larger space telescopes.
I examine mortuary, artifactual, symbolic, and proxemic data from Hopewell sites in southwestern and south-central Ohio to suggest that people associated with south-central Ohio sites such as Hopewell and Seip implemented more exclusionary political strategies, while people at southwestern sites such as Turner and Fort Ancient maintained a more corporate orientation through much of the Middle Woodland period. The recognition of this dimension of variation among Ohio Hopewell peoples has important implications for the study of the evolution of middle-range societies.
INTRODUCTION The direct anterior approach (DAA) and anterolateral approach (ALA) may be used for hip hemiarthroplasty (HHA) as a treatment for femoral neck fractures. The DAA often utilizes intraoperative fluoroscopy to determine leg length and offset, while the ALA traditionally utilizes an intraoperative clinical exam to determine offset and leg length. This study will evaluate two techniques: the “grid fluoroscopy [GF] technique” and the “intraoperative exam [IE] technique,” each performed by one of two separate surgeons, and compare each technique’s accuracy to restore leg length and femoral offset in a patient population that underwent HHA. METHODS Two investigators retrospectively reviewed charts of 208 randomly selected patients who had an HHA from either a DAA or ALA performed by two different surgeons for the treatment of femoral neck fractures. Postoperative AP pelvis radiographs were measured to determine offset and leg length compared with the non-operative extremity. Non-normal continuous variables were provided by median and interquartile range. Data were analyzed with the Mann-Whitney U test and Student’s t-test. RESULTS After inclusion and exclusion criteria, data were reviewed on 173 hemiarthroplasties. The mean age was 80.3 years (± 11.2 years). Of the surgical patients, 65.9% were female, and 70.9% identified their ethnicity as white. The DAA was used in 93 patients and ALA in 80 patients. Analysis comparing the two techniques demonstrated no statistically significant differences in median leg length between GF technique (1.02 IQR -0.1, 2.0 mm) and IE technique (1.25 IQR -2.4, 1.3 mm,) (p=0.67). There was also no statistically significant difference in offset between GF technique (1.3 IQR 0.2, 2.1 mm) and IE technique (0.6 IQR -2.7 mm, 3.2 mm) (p=0.13). However, a difference was found in mean length of surgery that was statistically significant. We found that the mean length of surgery for the IE technique was 74.8 ± 24.7 minutes versus the GF technique, which was 95.1 ± 23.0 minutes, (p<0.0001). DISCUSSION There was no significant difference between leg length and offset with the use of intraoperative fluoroscopy with DAA compared to no intraoperative imaging with ALA. Our study suggests that DAA and ALA are equally effective approaches for re-establishing symmetric leg length and offset in HHA for femoral neck fractures. In this study, the ALA had a shorter surgical time compared to DAA, potentially due to the utilization of intraoperative fluoroscopy for this particular technique during the DAA.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.