Overall, no significant differences were noted in mortality, length of stay, or pneumonia rates between severely injured trauma subjects with and without pulmonary contusions.
Potentials of mean force calculated for the diffusion of small guest molecules (CO(2) and CH(4)) between adjacent host cavities in the beta(0) p-tert-butylcalix[4]arene polymorph reveal sufficiently high barriers to diffusion to justify characterizing the lattice voids in this crystal as independent host cavities rather than as extended volumes. In addition, the calculated barrier heights are consistent with a "relay" model for gas diffusion in this ostensibly nonporous organic solid involving the lateral sliding of the host bilayers.
Clinical utility of algorithms to diagnose ventilator-associated pneumonia (VAP) in surgical patients has not been established. We aimed to test the diagnostic accuracy of two established methods to reliably diagnose VAP in acutely ill and injured surgical patients. After institutional review board approval, we prospectively collected data on 508 mechanically ventilated acute care surgery patients. Microbiologic samples were taken daily from all patients. Demographics, clinical, laboratory, and radiographic data were collected. The Johanson Criteria (JC) and Clinical Pulmonary Infection Score (CPIS) were calculated and analyzed. Sensitivity, specificity, and positive predictive values (PPV) and negative predictive value (NPV) were calculated in comparison to positive respiratory cultures. Of the 508 patients, 312 (61.4%) were acutely injured; emergent general surgery was performed in 141 (27.8%) patients, and 54 (10.6%) underwent elective operation. Positive respiratory cultures were identified in 198 (39%) of the 508 patients. JC diagnosed VAP in 291 (57.3%) patients (sensitivity 82.8%, specificity 59%, PPV 56.4%, NPV 84.3%, accuracy 68.3%). The CPIS resulted in 189 (37.2%) VAP diagnoses (sensitivity 61.1%, specificity 78.1%, PPV 64%, NPV 75.9%, and accuracy 71.5%). To address the inaccuracy of the algorithms, concordance testing was performed on the data to evaluate correlation between the algorithmic VAP diagnosis criteria and respiratory culture data. Nonconcordance with culture data diagnosis was identified with both JC (rho 0.41) and CPIS (rho 0.41). Sensitivity, specificity, PPV and NPV, and accuracy of both established clinical formulas was unacceptably low in acute care surgery patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.