BackgroundDespite the availability of effective therapies, heart failure (HF) remains a highly prevalent disease and the leading cause of hospitalizations in the U.S. Few data are available, however, describing changing trends in the use of various cardiac medications to treat patients with HF and factors associated with treatment. The objectives of this population-based study were to examine decade-long trends (1995 - 2004) in the use of several cardiac medications in patients hospitalized with acute decompensated heart failure (ADHF) and factors associated with evidence-based treatment.MethodsWe reviewed the medical records of 9,748 residents of the Worcester, MA, metropolitan area who were hospitalized with ADHF at all 11 central Massachusetts medical centers in 1995, 2000, 2002, and 2004.ResultsBetween 1995 and 2004, respectively, the prescription upon hospital discharge of beta-blockers (23%; 67%), angiotensin pathway inhibitors (47%; 55%), statins (5%; 43%), and aspirin (35%; 51%) increased markedly, while the use of digoxin (51%; 29%), nitrates (46%; 24%), and calcium channel blockers (33%; 22%) declined significantly; nearly all patients received diuretics. Patients in the earliest study year, those with a history of obstructive pulmonary disease or anemia, incident HF, non-specific symptoms, and women were less likely to receive beta blockers and angiotensin pathway inhibitors than respective comparison groups. In 2004, 82% of patients were discharged on at least one of these recommended agents; however, only 41% were discharged on medications from both recommended classes.ConclusionsOur data suggest that opportunities exist to further improve the use of HF therapeutics.
Orthopedic oncologists often encounter patients with minor bony lesions that are difficult to access surgically and therefore require large exposures out of proportion to the severity of disease that confer significant patient morbidity. Minimally invasive surgical techniques offer the advantage of smaller incisions, shorter operative times, decreased tissue damage, and decreased costs. A variety of surgical procedures have emerged using minimally invasive technologies, particularly in the field of spine surgery. Areas covered: In this article, we describe the Minimal Exposure Tubular Retractor (METRx) System which is a minimally invasive surgical device that utilizes a series of dilators to permit access to a surgical site of interest. This system was developed for use in treatment of disc herniation, spinal stenosis, posterior lumbar interbody fusion, transforaminal lumbar interbody fusion and spinal cord stimulation implantation. We also describe novel uses of this system for minimally invasive biopsy and treatment of benign and metastatic bone lesions at our institution. Expert commentary: Minimally invasive surgical techniques will continue to expand into the field of orthopedic oncology. With a greater number of studies proving the safety and effectiveness of this technique, the demand for minimally invasive treatments will grow.
Background Limited data exist, particularly from the more generalizable perspective of a community-wide investigation, about recent trends in ambulance use, and factors associated with ambulance use, in patients hospitalized with acute myocardial infarction. Objective The objectives of this population-based prospective epidemiologic study were to describe decade long trends (1997-2007) in the use of emergency medical services (EMS) by residents of the Worcester, Massachusetts, metropolitan area hospitalized for acute myocardial infarction (AMI) and to describe the characteristics of patients with AMI transported to the hospital by EMS (n=3,789) compared with those transported by other means (n=1,505). Methods The study population consisted of 5,294 patients hospitalized for AMI at 11 greater Worcester medical centers in 5 annual periods between 1997 and 2007. Information about the use of EMS, and factors associated with EMS use, were obtained through the review of hospital medical records. Results There was a progressive increase in the proportion of greater Worcester residents with AMI transported to central Massachusetts hospitals by ambulance over time (66.9% transported in 1997; 74.9% transported in 2007). Patients transported by EMS were older, more likely to be women, and to have a greater prevalence of previously diagnosed comorbidities. Conclusions Our findings provide encouragement for the use of EMS in residents of a large central New England community hospitalized with AMI. Despite increasing trends in ambulance use, more research is needed to explore the reasons why patients with AMI do not utilize EMS in the setting of an acute cardiac emergency.
Background: Percutaneous guide wire insertion for scaphoid screw fixation can be challenging and often requires multiple attempts with significant radiation exposure to the surgical team. A 3-dimensional (3D) printed targeting device has the potential to reduce procedure time and intraoperative radiation exposure. Methods: Our targeting device protocol included a preprocedure computed tomography (CT) scan of a casted cadaver wrist, followed by 3D printing of a customized targeting guide. In a comparison trial, seven orthopedic surgery residents performed percutaneous scaphoid guide wire insertion on different cadaver specimens by both freehand technique and using our targeting device. Radiation exposure and procedure times were compared. All specimens underwent postprocedure CT to assess Kirschner wire (K-wire) accuracy, determined by central third placement. Pre- and postprocedure CT scans from the targeting device group were co-registered to compare planned and actual K-wire trajectories. Results: Using the freehand technique, mean fluoroscopy time was 120 seconds (standard deviation: ±53 seconds) generating 2.45 milligray of radiation. Average procedure time was 21 minutes with a mean of 6.4 (range: 3-9) insertion attempts. A single insertion attempt was made using the targeting device with an average procedure time of 30 seconds and no fluoroscopy exposure. Four K-wires were placed within the central scaphoid in both groups. Using the targeting device, average linear deviation from the planned trajectory was 2.1 mm, while the maximum linear deviation was 3.75 mm. Conclusion: When compared to freehand scaphoid guide wire insertion, our targeting device provides similar accuracy while significantly reducing intraoperative radiation exposure and procedure time.
Ciprofloxacin-induced tendon rupture appears to be possible in the extensor digitorum communis tendons of the hand. Our patient was managed operatively and had a good functional outcome.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.