The span and range of an ion-selective electrode (ISE) has been identified by IUPAC as a potential or activity difference between the upper and lower detection limits of the electrode. Once the span is known, the ultimately attainable detection limit of the ISE can be calculated using its theoretical response slope. In this paper, we propose an original method for the determination of the ultimate span and response range of ISEs. The simple measurement of span is recommended to aid the fast screening of novel ionophores and help to focus optimization processes to the most promising candidates. The measurement of span is combined with a generally applicable procedure for the determination of the three seminal parameters of ISEs: the response slope, the ultimate selectivity coefficients, and detection limit. In the proposed procedure, following the span measurement, two subsequent exponential dilution experiments are completed in which the responses of the electrode for the primary and the interfering ions are tested using a solution of a discriminated ion and deionized water as diluting electrolytes in consecution. The advantages and the practical usefulness of the proposed methods and procedures are demonstrated through the evaluation of the performance characteristics of novel and well-characterized ionophore-based potassium and calcium sensors.
We describe here the fast LC-MS/MS separation of a mixture of neurotransmitters consisting of dopamine, epinephrine, norepinephrine, 3,4-dihydroxybenzylamine (DHBA), salsolinol, serotonin, and gamma-aminobutyric acid (GABA). The new UltiMate 3000 Rapid Separation system (RSLC) was successfully coupled to the 4000 QTRAP mass spectrometer operating in multiple-reaction monitoring (MRM) mode. The separation was attained using a 100 mm length, 2.2 microm particle size Acclaim column at a flow rate of 0.5 mL/min. The column back pressure was 350 bar, while the total run time including column re-equilibration was 5.2 min. The peak resolution was minimally affected by the fast separation. The RSLC-MRM separation was found to have a precision range based on peak area for 50 replicate runs of 2-5% CV for all analytes, and the reproducibility of the retention time for all analytes was found to range from 0-2% CV. The described method represents an almost seven times shorter analysis time of neurotransmitters using LC/MRM which is very useful in screening large quantities of biological samples for various neurotransmitters.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.