Abstract. Absorption photometers for real time application have been available since the 1980s, but the use of filterbased instruments to derive information on aerosol properties (absorption coefficient and black carbon, BC) is still a matter of debate. Several workshops have been conducted to investigate the performance of individual instruments over the intervening years. Two workshops with large sets of aerosol absorption photometers were conducted in 2005 and 2007. The data from these instruments were corrected using existing methods before further analysis. The intercomparison shows a large variation between the responses to absorbing aerosol particles for different types of instruments. The unit to unit variability between instruments can be up to 30% for Particle Soot Absorption Photometers (PSAPs) and Aethalometers. Multi Angle Absorption Photometers (MAAPs) showed a variability of less than 5%. Reasons for the high variability were identified to be variations in sample flow and spot size. It was observed that different flow rates influence system performance with respect to response to absorption and instrumental noise. Measurements with non absorbing particles showed that the current corrections of a cross sensitivity to particle scattering are not sufficient. Remaining cross sensitivities were found to be a function of the total particle load on the filter. The large variation between the response to absorbing aerosol particles for different types of instruments indicates that current correction functions for absorption photometers are not adequate.
Abstract. Long-term monitoring of the chemical composition of clouds (73 cloud events representing 199 individual samples) sampled at the puy de Dôme (pdD) station (France) was performed between 2001 and 2011. Physicochemical parameters, as well as the concentrations of the major organic and inorganic constituents, were measured and analyzed by multicomponent statistical analysis. Along with the corresponding back-trajectory plots, this allowed for distinguishing four different categories of air masses reaching the summit of the pdD: polluted, continental, marine and highly marine. The statistical analysis led to the determination of criteria (concentrations of inorganic compounds, pH) that differentiate each category of air masses. Highly marine clouds exhibited high concentrations of Na+ and Cl−; the marine category presented lower concentration of ions but more elevated pH. Finally, the two remaining clusters were classified as "continental" and "polluted"; these clusters had the second-highest and highest levels of NH4+, NO3−, and SO24−, respectively. This unique data set of cloud chemical composition is then discussed as a function of this classification. Total organic carbon (TOC) is significantly higher in polluted air masses than in the other categories, which suggests additional anthropogenic sources. Concentrations of carboxylic acids and carbonyls represent around 10% of the organic matter in all categories of air masses and are studied for their relative importance. Iron concentrations are significantly higher for polluted air masses and iron is mainly present in its oxidation state (+II) in all categories of air masses. Finally, H2O2 concentrations are much more varied in marine and highly marine clouds than in polluted clouds, which are characterized by the lowest average concentration of H2O2. This data set provides concentration ranges of main inorganic and organic compounds for modeling purposes on multiphase cloud chemistry.
Abstract. This paper presents the light-scattering properties of atmospheric aerosol particles measured over the past decade at 28 ACTRIS observatories, which are located mainly in Europe. The data include particle light scattering (σsp) and hemispheric backscattering (σbsp) coefficients, scattering Ångström exponent (SAE), backscatter fraction (BF) and asymmetry parameter (g). An increasing gradient of σsp is observed when moving from remote environments (arctic/mountain) to regional and to urban environments. At a regional level in Europe, σsp also increases when moving from Nordic and Baltic countries and from western Europe to central/eastern Europe, whereas no clear spatial gradient is observed for other station environments. The SAE does not show a clear gradient as a function of the placement of the station. However, a west-to-east-increasing gradient is observed for both regional and mountain placements, suggesting a lower fraction of fine-mode particle in western/south-western Europe compared to central and eastern Europe, where the fine-mode particles dominate the scattering. The g does not show any clear gradient by station placement or geographical location reflecting the complex relationship of this parameter with the physical properties of the aerosol particles. Both the station placement and the geographical location are important factors affecting the intra-annual variability. At mountain sites, higher σsp and SAE values are measured in the summer due to the enhanced boundary layer influence and/or new particle-formation episodes. Conversely, the lower horizontal and vertical dispersion during winter leads to higher σsp values at all low-altitude sites in central and eastern Europe compared to summer. These sites also show SAE maxima in the summer (with corresponding g minima). At all sites, both SAE and g show a strong variation with aerosol particle loading. The lowest values of g are always observed together with low σsp values, indicating a larger contribution from particles in the smaller accumulation mode. During periods of high σsp values, the variation of g is less pronounced, whereas the SAE increases or decreases, suggesting changes mostly in the coarse aerosol particle mode rather than in the fine mode. Statistically significant decreasing trends of σsp are observed at 5 out of the 13 stations included in the trend analyses. The total reductions of σsp are consistent with those reported for PM2.5 and PM10 mass concentrations over similar periods across Europe.
The noninvasive detection of Helicobacter pylori and its resistance to clarithromycin could revolutionize the management of H. pylori-infected patients by tailoring eradication treatment without any need for endoscopy when histology is not necessary. Several real-time PCR tests performed on stools have been proposed, but their performances were either poor or they were tested on too few patients to be properly evaluated. We conducted a prospective, multicenter study including 1,200 adult patients who were addressed for gastroduodenal endoscopy with gastric biopsies and who were naive for eradication treatment in order to evaluate the performance of the Amplidiag H. pylori+ClariR assay recently developed by Mobidiag (Espoo, Finland). The results of the Amplidiag H. pylori+ClariR assay performed on DNA from stools (automatic extraction with the EasyMag system [bioMérieux]) were compared with those of culture/Etest and quadruplex real-time PCRs performed on two gastric biopsy samples (from the antrum and corpus) to detect the H. pylori glmM gene and mutations in the 23S rRNA genes conferring clarithromycin resistance. The sensitivity and specificity of the detection of H. pylori were 96.3% (95% confidence interval [CI], 92 to 98%) and 98.7% (95% CI, 97 to 99%), respectively. The positive and negative predictive values were evaluated to be 92.2% (95% CI, 92 to 98%) and 99.3% (95% CI, 98 to 99%), respectively. In this cohort, 160 patients (14.7%) were found to be infected (positive by culture and/or PCR). The sensitivity and specificity for detecting resistance to clarithromycin were 100% (95% CI, 88 to 100%) and 98.4% (95% CI, 94 to 99%), respectively.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.