Southern Methodist University houses one of five existing commercially available UltraLo 1800 production model alpha counters made by XIA LLC. The instrument has an electron drift chamber with a 707 cm 2 or 1800 cm 2 counting region which is determined by selecting the inner electrode size. The SMU team operating this device is part of the SuperCDMS screening working group, and uses the alpha counter to study the background rates from the decay of radon in materials used to construct the SuperCDMS experiment. We have studied four acrylic samples obtained from the MiniCLEAN direct dark matter search with the XIA instrument demonstrating its utility in low background experiments by investigating the plate-out of 210 Pb and comparing the effectiveness of cleaning procedures in removing 222 Rn progenies from the samples.
Introduction The intracranial skull-base meningioma is in proximity to multiple critical organs and heterogeneous tissues. Steep dose gradients often result from avoiding critical organs in proton treatment plans. Dose uncertainties arising from setup errors under image-guided radiation therapy are worthy of evaluation. Patients and Methods Fourteen patients with skull-base meningioma were retrospectively identified and planned with proton pencil beam scanning (PBS) single-field uniform dose (SFUD) and multifield optimization (MFO) techniques. The setup uncertainties were assigned a probability model on the basis of prior published data. The impact on the dose distribution from nominal 1-mm and large, less probable setup errors, as well as the cumulative effect, was analyzed. The robustness of SFUD and MFO planning techniques in these scenarios was discussed. Results The target coverage was reduced and the plan dose hot spot increased by all setup uncertainty scenarios regardless of the planning techniques. For 1 mm nominal shifts, the deviations in clinical target volume (CTV) coverage D99% was −11 ± 52 cGy and −45 ± 147 cGy for SFUD and MFO plans. The setup uncertainties affected the organ at risk (OAR) dose both positively and negatively. The statistical average of the setup uncertainties had <100 cGy impact on the plan qualities for all patients. The cumulative deviations in CTV D95% were 1 ± 34 cGy and −7 ± 18 cGy for SFUD and MFO plans. Conclusion It is important to understand the impact of setup uncertainties on skull-base meningioma, as the tumor target has complex shape and is in proximity to multiple critical organs. Our work evaluated the setup uncertainty based on its probability distribution and evaluated the dosimetric consequences. In general, the SFUD plans demonstrated more robustness than the MFO plans in target coverages and brainstem dose. The probability-weighted overall effect on the dose distribution is small compared to the dosimetric shift during single fraction.
The decay of common radioactive gases, such as radon, produces stable isotopes by a sequence of daughter particles with varied half-lives. These daughter particles are a significant source of gamma, neutron, and alpha (α) particle backgrounds that can mimic desired signals in dark matter and neutrinoless double beta decay experiments. In the LUMINA Laboratory at Southern Methodist University (SMU), studies of radon plate-out onto copper samples are conducted using one of XIA's first five UltraLo 1800 alpha counters. We present results from investigations into various mitigation approaches. A custom-built copper holder (in either plastic or metal) has been designed and produced to maximize the copper's exposure to 220 Rn. The 220 Rn source is a collection of camping lantern mantles. We present the current status of control and experimental methods for addressing radon exposure levels.
Highly time-resolved mechanical measurements, modeling, and simulations show that large shear bands in bulk metallic glasses nucleate in a manner similar to cracks. When small slips reach a nucleation size, the dynamics changes and the shear band rapidly grows to span the entire sample. Smaller nucleation sizes imply lower ductility. Ductility can be increased by increasing the nucleation size relative to the maximum (“cutoff”) shear band size at the upper edge of the power law scaling range of their size distribution. This can be achieved in three ways: (1) by increasing the nucleation size beyond this cutoff size of the shear bands, (2) by keeping all shear bands smaller than the nucleation size, or (3) by choosing a sample size smaller than the nucleation size. The discussed methods can also be used to rapidly order metallic glasses according to ductility.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.