dClostridium difficile can carry a genetically variable pathogenicity locus (PaLoc), which encodes clostridial toxins A and B. In hospitals and in the community at large, this organism is increasingly identified as a pathogen. To develop a diagnostic test that combines the strengths of immunoassays (cost) and DNA amplification assays (sensitivity/specificity), we targeted a genetically stable PaLoc region, amplifying tcdB sequences and detecting them by hybridization capture. The assay employs a hot-start isothermal method coupled to a multiplexed chip-based readout, creating a manual assay that detects toxigenic C. difficile with high sensitivity and specificity within 1 h. Assay automation on an electromechanical instrument produced an analytical sensitivity of 10 CFU (95% probability of detection) of C. difficile in fecal samples, along with discrimination against other enteric bacteria. To verify automated assay function, 130 patient samples were tested: 31/32 positive samples (97% sensitive; 95% confidence interval [CI], 82 to 99%) and 98/98 negative samples (100% specific; 95% CI, 95 to 100%) were scored correctly. Largescale clinical studies are now planned to determine clinical sensitivity and specificity.
We describe here a strategy that can distinguish between Staphylococcus species truly present in a clinical sample from contaminating Staphylococcus species introduced during the testing process. Contaminating Staphylococcus species are present at low levels in PCR reagents and colonize lab personnel. To eliminate detection of contaminants, we describe an approach that utilizes addition of sufficient quantities of either non-target Staphylococcal cells (Staphylococcus succinus or Staphylococcus muscae) or synthetic oligonucleotide templates to helicase dependent isothermal amplification reactions to consume Staphylococcus-specific tuf and mecA gene primers such that contaminating Staphylococcus amplification is suppressed to below assay limits of detection. The suppressor template DNA is designed with perfect homology to the primers used in the assay but an internal sequence that is unrelated to the Staphylococcal species targeted for detection. Input amount of the suppressor is determined by a mathematical model described herein and is demonstrated to completely suppress contaminating levels of Staphylococcus while not negatively impacting the appropriate clinical assay limit of detection. We have applied this approach to improve the specificity of detection of Staphylococcus species present in positive blood cultures using a chip-based array that produces results visible to the unaided eye.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.