Background. Most patients adm itted to an intensive care unit (ICU) for mechanical ventilation require endotracheal intubation. Cuffed endotracheal tubes (ETTs) are utilised as they provide a better seal to facilitate ventilation and minimise aspiration. Complications due to overinflation or underinflation o f the cuff may occur. Neither the frequency o f in te rm itte nt cuff pressure (Pcuff) measurement nor the advantage o f continuous Pcuff m onitoring has been clearly established.Objective. To determ ine deviations in ETT Pcuff from the recommended range during the intervals between routine thrice-daily Pcuff measurements in adult ICU patients. Our key objective was to identify the extent and cause o f ETT Pcuff changes during these intervals. In addition, we attem pted to demonstrate the failure o f routine thrice-daily Pcuff m onitoring to detect the large variation in Pcuff o f patients throu gh ou t the day.Methods. This prospective, observational study was conducted in the King Edward VIII Hospital ICU, Durban, KwaZulu-Natal Province, South Africa. Ethical and institutional approval was obtained. Consent was obtained from patients' next o f kin. Interm ittent Pcuff was recorded using mechanical manometers, and continuous measurements using pressure transducers. Results. Thirty-five critically ill adult patients were enrolled. The mean study tim e was 11.1 h. The mean Pcuff was 25.6 (standard deviation 7.1) cmH20 for the interm ittent group and 26.6 (8.7) cmH20 for the continuous group.The interm ittent pressure measurements were in the low-pressure range (<20 cmH20) 12% of the tim e compared w ith 83% in the target pressure range (20 -30 cmH20) and 5% in the high-pressure range (>30 cmH20). For continuous pressures, 13% o f the tim e was spent in the low-pressure range, 64% in the target pressure range, and 23% in the high-pressure range. For the entire study, 588 events causing Pcuff alterations were recorded. Conclusion. Continuous m onitoring o f Pcuff indicated that the endotracheal Pcuff varied extensively during mechanical ventilation in critically ill patients, such variation being noted both between patients and w ithin individual patients. Variations in individual patients occurred both during intrinsic patient activities and those of ICU personnel as part of routine patient maintenance. Interm ittent m onitoring may not detect these variations. Continuous m onitoring of Pcuff during mechanical ventilation in ICUs is thus recommended for all patients.S
Introduction: The aim of this study was to establish the most reliable standard method for monitoring endotracheal tube cuff pressure in an intensive care unit. Methodology: The study was conducted at King Edward VIII Hospital ICU on adult patients undergoing prolonged intubation of more than 24 hours. Consent was obtained from the patient’s next of kin. The patient’s Pcuff for this study was recorded in two ways simultaneously for a period of 12 hours during the day. The principal investigator recorded the Pcuff thrice during the study period using the Posey cufflator®. Continuous recording was done using a pressure transducer connected to the Nihon Kohden BSM®. Factors causing changes in Pcuff were also documented. Results: Thirty-five critically ill adult patients were enrolled into the study. Nineteen (54.3%) of the subjects were male. Seventeen out of 35 subjects were studied for the entire 720 minute period. The mean time of study of the group was 667 minutes with the lowest period being 135 minutes for one patient. The group mean ± Standard deviation (SD) was 26.6 8.7 with a 95% confidence index of 9.2 – 44.0 and the median value was 25 for continuous readings. For the entire group, 13% of the time was spent in the low pressure range (< 20 cmH2O), while 23% was spent in the high pressure (> 30 cmH2O). A mean of 64% of the time was spent in the normal pressure range. Overall, the most frequently encountered events that caused pressure changes were body movement, coughing, head movement and suctioning accounting for 26.2%, 20.1%, 19.2% and 9.4% respectively. For intermittent readings, the mean ± SD of all patients for T0 was 25.3 ± 6.9; for T6 25.9 ± 8.7 and for T12 24.8 ± 3.8. The overall mean ± SD for all readings was 25.6 ± 7.1. For the entire group, 12% of the time was spent in the low pressure range (< 20 cmH2O), while 5% was spent in the high pressure (> 30 cmH2O). A mean of 83% of the time was spent in the normal pressure range. The correlation between intermittent pressure and the continuous reading at the same time was r = 0.87. iii Discussion: Continuous monitoring of Pcuff indicated that the endotracheal cuff pressure varies extensively during mechanical ventilation in critically ill patients, such variation being noted both between patients and within an individual patient. In an attempt to compare intermittent and continuous monitoring of endotracheal cuff pressures, a good correlation between the two measurements was demonstrated. However, the variations in pressures noted for an individual patient would not have been detected if endotracheal cuff pressures were monitored intermittently. Hence, with continuous monitoring the pressure changes may be detected early. Conclusion: Continuous monitoring of cuff pressure during mechanical ventilation in intensive care units is thus recommended for all patients. If intermittent monitoring is performed, it should be more frequently than eight-hourly. It is recommended that a pressure range of 20-30 cmH2O still be used as the normal range. The role of self adjusting pressure devices, although needing further exploration, holds much promise.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.