Background COVID-19 has resulted in significant morbidity and mortality worldwide. Lateral flow assays can detect anti-Severe Acute Respiratory Syndrome Coronavirus-2 (SARS-CoV-2) antibodies to monitor transmission. However, standardized evaluation of their accuracy and tools to aid in interpreting results are needed. Methods We evaluated 20 IgG and IgM assays selected from available tests in April 2020. We evaluated the assays’ performance using 56 pre-pandemic negative and 56 SARS-CoV-2-positive plasma samples, collected 10–40 days after symptom onset, confirmed by a molecular test and analyzed by an ultra-sensitive immunoassay. Finally, we developed a user-friendly web app to extrapolate the positive predictive values based on their accuracy and local prevalence. Results Combined IgG + IgM sensitivities ranged from 33.9 to 94.6%, while combined specificities ranged from 92.6 to 100%. The highest sensitivities were detected in Lumiquick for IgG (98.2%), BioHit for both IgM (96.4%), and combined IgG + IgM sensitivity (94.6%). Furthermore, 11 LFAs and 8 LFAs showed perfect specificity for IgG and IgM, respectively, with 15 LFAs showing perfect combined IgG + IgM specificity. Lumiquick had the lowest estimated limit-of-detection (LOD) (0.1 μg/mL), followed by a similar LOD of 1.5 μg/mL for CareHealth, Cellex, KHB, and Vivachek. Conclusion We provide a public resource of the accuracy of select lateral flow assays with potential for home testing. The cost-effectiveness, scalable manufacturing process, and suitability for self-testing makes LFAs an attractive option for monitoring disease prevalence and assessing vaccine responsiveness. Our web tool provides an easy-to-use interface to demonstrate the impact of prevalence and test accuracy on the positive predictive values.
Objective To compare postoperative pain and analgesic use in children following transcanal endoscopic ear surgery (TEES) vs non–transcanal endoscopic ear surgery (non-TEES). Study Design Prospective case series. Setting Tertiary care center. Methods Surveys using the Wong-Baker FACES Pain Rating Scale and recording the frequency and dosage of consumed analgesics were administered prospectively to caregivers of children undergoing otologic surgery between May 2018 to February 2020. Pain intensity and medication use were recorded twice daily for 6 days, starting on postoperative day 0. Mean pain scores and mean number of consumed analgesic doses were compared between groups. Results Survey response rate was 57.9%. Among 53 patients who completed the survey, 35 (66.0%) underwent TEES and 18 (34.0%) underwent non-TEES. Mean pain ratings on postoperative days 0 and 1 were significantly lower among children undergoing TEES (2.2 and 2.1) vs non-TEES (4.0 and 4.1), P = .045 and P = .008, respectively (Mann-Whitney U test). The mean pain ratings across the 6 days were similar in TEES (1.7) and non-TEES (2.6) ( P = .140, Mann-Whitney U test). The mean number of analgesic doses consumed per half-day over the 6 days was significantly lower among children undergoing TEES (0.3) vs non-TEES (0.6; P = .049, Mann-Whitney U test). Conclusion Postoperative pain following TEES and non-TEES in children was overall low. Children undergoing TEES had a small but statistically significant decrease in pain on postoperative days 0 and 1 and decreased use of pain medications compared to non-TEES.
Background: COVID-19 has resulted in significant morbidity and mortality worldwide. Lateral flow assays can detect anti-Severe Acute Respiratory Syndrome Coronavirus-2 (SARS-CoV-2) antibodies to monitor transmission. However, standardized evaluation of their accuracy and tools to aid in interpreting results are needed.Methods: We evaluated 20 IgG and IgM assays selected from available tests in April 2020. We evaluated the assays’ performance using 56 pre-pandemic negative and 56 SARS-CoV-2-positive plasma samples, collected 10-40 days after symptom onset, confirmed by a molecular test and analyzed by an ultra-sensitive immunoassay. Finally, we developed a user-friendly web app to extrapolate the positive predictive values based on their accuracy and local prevalence.Results: Combined IgG+IgM sensitivities ranged from 33.9% to 94.6%, while combined specificities ranged from 92.6% to 100%. The highest sensitivities were detected in Lumiquick for IgG (98.2%), BioHit for both IgM (96.4%), and combined IgG+IgM sensitivity (94.6%). Furthermore, 11 LFAs and 8 LFAs showed perfect specificity for IgG and IgM, respectively, with 15 LFAs showing perfect combined IgG+IgM specificity. Lumiquick had the lowest estimated limit-of-detection (LOD) (0.1 mg/mL), followed by a similar LOD of 1.5 mg/mL for CareHealth, Cellex, KHB, and Vivachek.Conclusion: We provide a public resource of the accuracy of select lateral flow assays with potential for home testing. The cost-effectiveness, scalable manufacturing process, and suitability for self-testing makes LFAs an attractive option for monitoring disease prevalence and assessing vaccine responsiveness. Our web tool provides an easy-to-use interface to demonstrate the impact of prevalence and test accuracy on the positive predictive values.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.