Background:Residual right ventricular outflow obstruction during Tetralogy of Fallot repair necessitates peri-operative revision often requiring trans-annular patch with its negative sequels. Bidirectional Glenn shunt in this setting reduces trans-pulmonary gradient to avoid revision.Methods:Bidirectional Glenn shunt was added during Tetralogy repair in patients with significant residual obstruction. A total of 53 patients between January, 2011 and June, 2018 were included. Final follow-up was conducted in July, 2018.Results:Mean age at operation was 5.63±3.1 years. Right to left ventricular pressure ratio reduced significantly (0.91±0.09 versus 0.68±0.05; p<0.001) after bidirectional Glenn, avoiding revision in all cases. Glenn pressures at ICU admission decreased significantly by the time of ICU discharge (16.7±3.02 versus 13.5±2.19; p<0.001). Pleural drainage ≥ 7 days was seen in 14 (26.4%) patients. No side effects related to bidirectional Glenn-like facial swelling or veno-venous collaterals were noted. Mortality was 3.7%. Discharge echocardiography showed a mean trans-pulmonary gradient of 32.11±5.62 mmHg that decreased significantly to 25.64±5 (p<0.001) at the time of follow-up. Pulmonary insufficiency was none to mild in 45 (88.2%) and moderate in 6 (11.8%). Mean follow-up was 36.12±25.15 months (range 0.5–90). There was no interim intervention or death. At follow-up, all the patients were in NYHA functional class 1 with no increase in severity of pulmonary insufficiency.Conclusion:Supplementary bidirectional Glenn shunt significantly reduced residual right ventricular outflow obstruction during Tetralogy of Fallot repair avoiding revision with satisfactory early and mid-term results.
Pseudoaneurysm of ascending aorta is potentially fatal but well-recognized and infrequent complication after cardiac surgeries. The presentation can be varied and may develop early as in our case or may develop even after years. Our patient had VSD closure along with RV band Resection four month earlier to the development of pseudoaneurym. Transcatheter device closure was performed with 24mm atrial setal occluder without any procedural complication. To the best of our knowledge this is the largest device ever used for closure of post surgical pseudoaneurysm.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.