Three methods were explored to estimate the efficiency for the conversion of mechanical power to electrical power using synchronous generators in ships at low power factors. Generally, the generator efficiency data is provided by manufacturers as shop trial data and is measured by operating generators under power factor of 0.8 and 1.0. However, the efficiency of synchronous generators is not measured under low power factor of less than 0.8. In practice, onboard generators occasionally operate at low power factor and it is desirable to clarify their characteristics for power system designers of large vessels. By substituting the shop trial data into the proposed efficiency estimation formulas, the generator efficiency at low power factor was extrapolated. To evaluate the validity of these methods, the fuel consumption characteristics of diesel engines as prime movers was focused. The estimation of the generator efficiency was indirectly validated using a statistical analysis of long-term observational data of the generator in operation. As a result, the efficiency estimation method based on a power loss mechanism gave the most reliable result among the three estimation methods. The root mean squared error of the calculated specific fuel consumption was 3.5 g/kWh, which is approximately 1.66 % error rate.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.