A robust, reproducible, and single-step interface design between low flow rate separation techniques, such as sheathless capillary electrophoresis (CE) and nanoliquid chromatography (nLC), and mass spectrometry (MS) using electrospray ionization (ESI), is introduced. In this design, the electrical connection to the capillary outlet was achieved through a porous tip at the capillary outlet. The porous section was created by removing 1-1.5 in. of the polyimide coating of the capillary and etching this section by 49% solution of HF until it is porous. The electrical connection to the capillary outlet is achieved simply by inserting the capillary outlet containing the porous tip into the existing ESI needle (metal sheath) and filling the needle with the background electrolyte. Redox reactions of water at the ESI needle and transport of these small ions through the porous tip into the capillary provides the electrical connection for the ESI and for the CE outlet electrode. The etching process reduces the wall thickness of the etched section, including the tip of the capillary, to 5-10 microm, which for a 20-30 microm i.d. capillary results in stable electrospray at approximately 1.5 kV. The design is suitable for interfacing a wide range of capillary sizes with a wide range of flow rates to MS via ESI, but it is especially useful for interfacing narrow (<30 microm i.d.) capillaries and low flow rates (<100 nL/min). The advantages of the porous tip design include the following: (1) its fabrication is reproducible, can be automated, and does not require any mechanical tools. (2) The etching process reduces the tip outer diameter and makes the capillary porous in one step. (3) The interface can be used for both nLC-MS and CE-MS. (4) If blocked or damaged, a small section of the tip can be etched off without any loss of performance. (5) The interface design leaves the capillary inner wall intact and, therefore, does not add any dead volume to the CE-MS or nLC-MS interface. (6) Bubble formation due to redox reactions of water at the high-voltage electrode is outside of the separation capillary and does not affect separation or MS performances. The performance of this interface is demonstrated by the analyses of amino acids, peptide, and protein mixtures.
Capillary electrophoresis (CE) mass spectrometry (MS), with its ability to separate compounds present in extremely small volume samples rapidly, with high separation efficiency, and with compound identification capability based on molecular weight, is an extremely valuable analytical technique for the analysis of complex biological mixtures. The highest sensitivities and separation efficiencies are usually achieved by using narrow capillaries (5-50 micro m i.d.) and by using sheathless CE-to-MS interfaces. The difficulties in CE-to-MS interfacing and the limited loadability of these narrow columns, however, have prevented CE-MS from becoming a widely used analytical technique. To remedy these limitations, several CE-MS interfacing techniques have recently been introduced. While electrospray ionization is the most commonly used ionization technique for interfacing CE-to-MS, matrix assisted laser desorption ionization has also been used, using both on-line and off-line techniques. Moreover, the high concentration detection limit of CE has been addressed by development of several sample concentration and sample focusing methods. In addition, a wide variety of techniques such as capillary zone electrophoresis, capillary isoelectric focusing, and on-column transient isotachophoresis have now been interfaced to MS. These advances have resulted in a rapid increase in the use of CE-MS in the analysis of complex biological mixtures. CE-MS has now been successfully applied to the analysis of a wide variety of compounds including amino acids, protein digests, protein mixtures, single cells, oligonucleotides, and various small molecules relevant to the pharmaceutical industry.
A new capillary electrophoresis/mass spectrometry technique is introduced for attomole detection of primary amines (including several neurotransmitters), amino acids, and their d/l enantiomers in one run through the use of a complexation reagent while using only approximately 1 nL of sample. The technique uses underivatized amino acids in conjunction with an underivatized capillary, which significantly reduces cost and analysis time. It was found that when (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid (18-C-6-TCA, MW 440) was used as the background electrolyte/complexation reagent during the capillary electrophoresis/electrospray ionization-mass spectrometry (CE/ESI-MS) analysis of underivatized amino acids, stable complexes were formed between the amino acids and the 18-C-6-TCA molecules. These complexes, which exhibited high ionization efficiencies, were detectable at attomole levels for most amino acids. The detection limits of the AA/18-C-6-TCA complexes were on the average more than 2 orders of magnitude lower than that of the free amino acids in solution. In addition to lower detection limits under CE/ESI-MS, a solution of 18-C-6-TCA in the concentration range of 5-30 mM provided high separation efficiency for mixtures of l-amino acids as well as mixtures of d/l-amino acids. By using a solution of 18-C-6-TCA as the background electrolyte in conjunction with an underivatized, 130-cm-long, 20-microm-i.d., 150-microm-o.d. fused-silica capillary and by monitoring the m/z range of the amino acid/18-C-6-TCA complexes (m/z 515-700), most of the standard amino acids and many of their enantiomers were separated and detected with high separation efficiency and high sensitivity (nanomolar concentration detection limits) in one run. The solutions of 18-C-6-TCA also worked well as the CE/ESI-MS BGE for low-level detection of several neurotransmitters and some of their d/l enantiomers as well as for the analysis of amino acids at endogenous levels in lysed red blood cells.
Capillary electrophoresis/electrospray ionization-mass spectrometry (CE/ESI-MS) was applied to the analysis of underivatized amino acids and the separation of their D/L-enantiomers. Under full-scan mode, all standard protein amino acids were separated and detected at low-femtomole levels using a 130-cm-long, 20-microm-i.d., 150-microm-o.d. underivatized fused-silica capillary with 1 M formic acid as the background electrolyte. The CE/ESI-MS technique was also applied to the separation of L-arginine from L-canavanine (a close analogue of arginine where the terminal methylene linked to the guanidine group of arginine is replaced by an oxygen atom) in a complex mixture containing all standard protein amino acids. The utility of CE/ESI-MS in the analysis of real-world samples was demonstrated by the identification of two metabolic diseases (PKU and tyrosinemia) through blood analysis with minimal sample preparation. In addition, the on-line separation of 11 underivatized L-amino acids from their D-enantiomers was achieved by using a 30 mM solution of (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid as the background electrolyte.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.