Abstract:The invasive shrub, Acacia longifolia, native to southeastern Australia, has a negative impact on vegetation and ecosystem functioning in Portuguese dune ecosystems. In order to spectrally discriminate A. longifolia from other non-native and native species, we developed a classification model based on leaf reflectance spectra (350-2500 nm) and condensed leaf tannin content. High variation of leaf tannin content is common for Mediterranean shrub and tree species, in particular between N-fixing and non-N-fixing species, as well as within the genus, Acacia. However, variation in leaf tannin content has not been studied in coastal dune ecosystems in southwest Portugal. We hypothesized that condensed tannin concentration varies significantly across species, further allowing for distinguishing invasive, nitrogen-fixing A. longifolia from other vegetation based on leaf spectral reflectance data. Spectral field measurements were carried out using an ASD FieldSpec FR spectroradiometer attached to an ASD leaf clip in order to collect 750 in situ leaf reflectance spectra of seven frequent plant species at three study sites in southwest Portugal. We applied partial least squares (PLS) regression to predict the obtained leaf reflectance spectra of A. longifolia individuals to their corresponding tannin concentration. OPEN ACCESSRemote Sens. 2015, 7 1226A. longifolia had the lowest tannin concentration of all investigated species. Four wavelength regions (675-710 nm, 1060-1170 nm, 1360-1450 nm and 1630-1740 nm) were identified as being highly correlated with tannin concentration. A spectra-based classification model of the different plant species was calculated using a principal component analysis-linear discriminant analysis (PCA-LDA). The best prediction of A. longifolia was achieved by using wavelength regions between 1360-1450 nm and 1630-1740 nm, resulting in a user's accuracy of 98.9%. In comparison, selecting the entire wavelength range, the best user accuracy only reached 86.5% for A. longifolia individuals.
The aim of this study was to investigate the phase transitions occurring in nitrofurantoin and theophylline formulations during pelletization by extrusion-spheronization. An at-line process analytical technology (PAT) approach was used to increase the understanding of the solid-state behavior of the active pharmaceutical ingredients (APIs) during pelletization. Raman spectroscopy, near-infrared (NIR) spectroscopy, and X-ray powder diffraction (XRPD) were used in the characterization of polymorphic changes during the process. Samples were collected at the end of each processing stage (blending, granulation, extrusion, spheronization, and drying). Batches were dried at 3 temperature levels (60°C, 100°C, and 135°C). Water induced a hydrate formation in both model formulations during processing. NIR spectroscopy gave valuable real-time data about the state of water in the system, but it was not able to detect the hydrate formation in the theophylline and nitrofurantoin formulations during the granulation, extrusion, and spheronization stages because of the saturation of the water signal. Raman and XRPD measurement results confirmed the expected pseudopolymorphic changes of the APIs in the wet process stages. The relatively low level of Raman signal with the theophylline formulation complicated the interpretation. The drying temperature had a significant effect on dehydration. For a channel hydrate (theophylline), dehydration occurred at lower drying temperatures. In the case of isolated site hydrate (nitrofurantoin), dehydration was observed at higher temperatures. To reach an understanding of the process and to find the critical process parameters, the use of complementary analytical techniques are absolutely necessary when signals from APIs and different excipients overlap each other.
Abstract. The purpose of this research was to create a calibration model based on near-infrared (NIR) spectroscopy data obtained during a small-scale coating process to predict in-line the coating layer thickness of tablets coated in a side-vented drum coater. The developed setup for the small-scale coating process consisted of a rotating plate with 20 tablets molds that pass a spraying unit, a heating unit, and an in-line NIR spectroscopy probe during one rotation. High-density polyethylene (HDPE) was compressed to flat-faced tablets, and these were coated with a sustained release coating suspension containing Kollicoat IR and Kollicoat SR 30D. The film thickness of these tablets was determined for each tablet individually with a digital micrometer. A calibration model of predicted film thickness versus real-film thickness using PLS regression was developed. This model was tested against in-line NIR data obtained from a coating drum process, in which biconvex HDPE tablets were film-coated with the same filmcoating suspension. The model predicted a final coating thickness of 240 μm, while the measured average thickness (n = 100 tablets) was 210 μm. Taking into account the use of a different setup and differently shaped tablets, it was possible to predict the coating thickness with accuracy comparable to the one of the digital micrometer. Thus, the small-scale rotating plate system was found to be an efficient means of preparing calibration model for a tablet-coating drum process.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.