The incidence of RAO by vascular ultrasound was higher than expected from previous data, especially in patients who underwent the procedure with larger sheaths.
SwedenTo cite this article: Pavlova A, Delev D, Lacroix-Desmazes S, Schwaab R, Mende M, Fimmers R, Astermark J, Oldenburg J. Impact of polymorphisms of the major histocompatibility complex class II, interleukin-10, tumor necrosis factor-a and cytotoxic T-lymphocyte antigen-4 genes on inhibitor development in severe hemophilia A. J Thromb Haemost 2009; 7: 2006-15. Summary. Background: Approximately 25% of severe hemophilia A (HA) patients develop antibodies to factor VIII protein. Patients: In the present case-controlled cohort study, 260 severely affected, mutation-type-matched HA patients were studied for association of human leukocyte antigen (HLA) class II molecules and polymorphisms in the genes encoding interleukin-10 (IL-10), tumor necrosis factor-a (TNF-a) and cytotoxic T-lymphocyte antigen-4 (CTLA-4) and development of inhibitors. Results: Our results demonstrate a higher frequency of DRB1*15 and DQB1*0602 alleles as well as of the haplotype DRB1*15/DQB1*0602 in inhibitor patients [odds ratio (OR) 1.9; P < 0.05]. In TNF-a, the A allele of the )308G>A polymorphism was found with higher frequency in the inhibitor cohort (0.22 vs. 0.13, OR 1.80). This finding was more pronounced for the homozygous A/A genotype (OR 4.7). For IL-10, the )1082G allele was observed more frequently in patients with inhibitors (0.55 vs. 0.43; P = 0.008). The functional cytokine phenotype was determined for the first time, on the basis of the genetic background, and this showed that 12% of patients with inhibitors were high-TNF-a/high-IL-10 producers, as compared with 3% of non-inhibitor patients (OR 4.4). A trend for a lower frequency of the A allele of the CT60 polymorphism in CTLA-4 was found in inhibitor patients (0.42 vs. 0.50). Conclusions: In conclusion, the reported data clearly highlighted the participation of HLA molecules in inhibitor formation in a large cohort of patients. The higher frequencies of the )308G>A polymorphism in TNF-a and )1082A>G in IL-10 in inhibitor patients confirmed the earlier published data. The CT60 single-nucleotide polymorphism in CTLA-4 is of apparently less importance.
Background and Purpose-Diagnosis of paroxysmal atrial fibrillation is difficult but highly relevant in patients presenting withcerebral ischemia yet free from atrial fibrillation on admission. Early initiation and prolongation of continuous Holter monitoring may improve diagnostic yield compared with the standard of care including a 24-hour Holter recording. Methods-In the observational Find-AF trial (ISRCTN 46104198), consecutive patients presenting with symptoms of cerebral ischemia were included. Patients free from atrial fibrillation at presentation received 7-day Holter monitoring. Results-Two hundred eighty-one patients were prospectively included. Forty-four (15.7%) had atrial fibrillation documented by routine electrocardiogram on admission. All remaining patients received Holter monitors at a median of 5.5 hours after presentation. In those 224 patients who received Holter monitors but had no previously known paroxysmal atrial fibrillation, the detection rate with early and prolonged (7 days) Holter monitoring (12.5%) was significantly higher than for any 24-hour (mean of 7 intervals: 4.8%, Pϭ0.015) or any 48-hour monitoring interval (mean of 6 intervals: 6.4%, Pϭ0.023). Of those 28 patients with new atrial fibrillation on Holter monitoring, 15 (6.7%) had been discharged without therapeutic anticoagulation after routine clinical care (ie, with data from 24-hour Holter monitoring only). Detection rates were 43.8% or 6.3% for short supraventricular runs of Ն10 beats or prolonged episodes (Ͼ5 hours) of atrial fibrillation, respectively. Diagnostic yield appeared to be only slightly and not significantly increased during the first 3 days after the index event. Conclusions-Prolongation of Holter monitoring in patients with symptoms of cerebral ischemic events increases the rate of detection of paroxysmal atrial fibrillation up to Day 7, leading to a relevant change in therapy in a substantial number of patients. Early initiation of monitoring does not appear to be crucial. Hence, prolonged Holter monitoring (Ն7 days) should be considered for all patients with unexplained cerebral ischemia. (Stroke. 2010;41:2884-2888.)
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.