In encoderless Model Predictive Torque Control (MPTC) of three-phase Induction Motor (IM) drives, current sensors can face different electrical or mechanical faults in harsh industrial environments. In this research, single-phase current sensor Fault-Tolerant Control (FTC) method for MPTC of three-phase IM drives without speed measurement using a flux linkage observer and Model Reference Adaptive System (MRAS) algorithm is proposed. In the presented FTC method, Third-Difference (TD) operators, logic circuit module, flux linkage observer, and MRAS algorithm are utilized for fault detection, fault isolation, estimation of stator currents and fluxes, and speed estimation, respectively. In comparison with the conventional current sensor FTC methods, the proposed method can be utilized for encoderless three-phase IM drives. In order to confirm the usefulness and possibility of the proposed encoderless FTC method, experimental studies are performed for a 0.75 kW three-phase IM drive system in different situations. The achieved results demonstrate good performances of the proposed technique during both normal and faulty situations.
In encoderless Model Predictive Torque Control (MPTC) of three-phase Induction Motor (IM) drives, current sensors can face different electrical or mechanical faults in harsh industrial environments. In this research, single-phase current sensor Fault-Tolerant Control (FTC) method for MPTC of three-phase IM drives without speed measurement using a flux linkage observer and Model Reference Adaptive System (MRAS) algorithm is proposed. In the presented FTC method, Third-Difference (TD) operators, logic circuit module, flux linkage observer, and MRAS algorithm are utilized for fault detection, fault isolation, estimation of stator currents and fluxes, and speed estimation, respectively. In comparison with the conventional current sensor FTC methods, the proposed method can be utilized for encoderless three-phase IM drives. In order to confirm the usefulness and possibility of the proposed encoderless FTC method, experimental studies are performed for a 0.75 kW three-phase IM drive system in different situations. The achieved results demonstrate good performances of the proposed technique during both normal and faulty situations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.