The efficient development and utilisation of magnetic nanoparticles (MNPs) for applications in enhanced biosensing relies on the use of magnetisation dynamics, which are primarily governed by the time-dependent motion of the magnetisation due to externally applied magnetic fields. An accurate description of the physics involved is complex and not yet fully understood, especially in the frequency range where Néel and Brownian relaxation processes compete. However, even though it is well known that non-zero, non-static local fields significantly influence these magnetisation dynamics, the modelling of magnetic dynamics for MNPs often uses zero-field dynamics or a static Langevin approach. In this paper, we developed an approximation to model and evaluate its performance for MNPs exposed to a magnetic field with varying amplitude and frequency. This model was initially developed to predict superparamagnetic nanoparticle behaviour in differential magnetometry applications but it can also be applied to similar techniques such as magnetic particle imaging and frequency mixing. Our model was based upon the Fokker–Planck equations for the two relaxation mechanisms. The equations were solved through numerical approximation and they were then combined, while taking into account the particle size distribution and the respective anisotropy distribution. Our model was evaluated for Synomag®-D70, Synomag®-D50 and SHP-15, which resulted in an overall good agreement between measurement and simulation.
Nonlinear handheld detection of magnetic nanoparticles is used to assess the lymph node status of cancer patients. Joint sensitivity and resolving power of nonlinear handheld detection can be maximized by optimizing the frequency of the excitation field, which is strongly influenced by Brownian and Néel relaxation. The characteristic frequency of magnetic nanoparticles that defines sensitivity and resolving power is usually assessed by AC susceptometry. In this study, we used SPaQ data to predict handheld detection performance for magnetic nanoparticles with various particle sizes. SPaQ assesses dynamics by measuring the derivative of the magnetization originating from magnetic nanoparticles activated by an alternating excitation field. The ratio between the maximum signal difference and full-width-at-half-maximumis used to estimate the optimal excitation frequency. Thereupon, it was shown that a particle with a combination of Brownian and Néel relaxation is superior in nonlinear handheld detection compared to Brownian or Néel only particles. Moreover, the optimal excitation frequency is generally established at a slightly higher frequency compared to the characteristic frequency assessed by AC susceptometry. Consequently, this insight into the consequences of the dynamic behavior of magnetic nanoparticles under an alternating magnetic field enables the optimization of nonlinear handheld detection for specific clinical applications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.