A modeling method of regional integrated energy system based on bus method and transient simulation is proposed, and the system optimization is based on the dynamic balance of supply and demand in the whole year energy supply cycle. A CCHP system of gas turbine coupled with ground source heat pump and electric refrigeration unit is constructed. The energy relationship of the system is described by bus structure, and the transient calculation model is built on TRNSYS platform. The weighted sum of annual total cost saving rate, primary energy saving rate and environmental pollutant shadow cost saving rate is taken as the optimized objective function, and on the basis of annual dynamic balance, the Hooke-Jeeves algorithm is used for optimization of the system configuration. A complex commercial area in Beijing is taken as an example, and different weighting coefficients are set for optimization of the system configuration. The results show that, from the perspective of economy, environmental benefit and primary energy consumption, performance of the system increases and then decreases with rise of gas turbine power; under the simulated cooling/heating load, the maximum number of optimum configuration is seen in the combination of 35 kW gas turbine + 723 kW GSHP and 1178 kW electric chiller; in comparison with traditional distributed system, the annual cost saving rate, primary energy saving rate and environmental pollutant shadow cost saving rate of the system are 29.4%, 49.6% and 58.2%, respectively.
Although the Combined Cooing, Heating and Power System (hereinafter referred to as "CCHP") improves the capacity utilization rate and energy utilization efficiency, single use of CCHP system cannot realize dynamic matching between supply and demand loads due to the unbalance features of the user's cooling and heating loads. On the basis of user convenience and wide applicability of clean air energy, this paper tries to put forward a coupled CCHP system with combustion gas turbine and ASHP ordered power by heat, analyze trends of such parameters as gas consumption and power consumption of heat pump in line with adjustment of heating load proportion of combustion gas turbine, and optimize the system ratio in the method of annual costs and energy environmental benefit assessment. Based on the analysis of the hourly simulation and matching characteristics of the cold and hot load of the 100 thousand square meter building, it is found that the annual cost of the air source heat pump is low, but the energy and environmental benefits are poor. It will lead to 6.35% shortage of cooling load in summer. Combined with the evaluation method of primary energy consumption and zero carbon dioxide emission, the coupling system of CHHP and air source heat pump with 41% gas turbine load ratio is the best configuration. This system structure and optimization method can provide some reference for the development of CCHP coupling system.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.