Surface tethered single-stranded DNA films are relevant biorecognition layers for oligonucleotide sequence identification. Also, hydration induced effects on these films have proven useful for the nanomechanical detection of DNA hybridization. Here, we apply nanomechanical sensors and atomic force microscopy to characterize in air and upon varying relative humidity conditions the swelling and deswelling of grafted single stranded and double stranded DNA films. The combination of these techniques validates a two-step hybridization process, where complementary strands first bind to the surface tethered single stranded DNA probes and then slowly proceed to a fully zipped configuration. Our results also demonstrate that, despite the slow hybridization kinetics observed for grafted DNA onto microcantilever surfaces, ex-situ sequence identification does not require hybridization times typically longer than 1 hour, while quantification is a major challenge.. 2
Microcantilever based sensors are promising devices because they are fast, low cost, portable and allow measuring extremely small quantities of substances in gas or liquid phase that are not detectable by other methods. In this work we investigate the swelling and deswelling behavior of poly(hydroxyl ethyl methacrylate), PHEMA, films with three different average molecular masses deposited onto bare silicon microcantilevers, a hydrophilic substrate, and onto polystyrene (PS) coated microcantilevers, which is a hydrophobic substrate, under humidity cycles by monitoring the deflections resulting from differential surface stress. The results found in the present study demonstrate that the micromechanical response observed are related not only to the polymer molecular weight, but also to the polymer-interface phenomena and environment-polymer interface that can play a crucial role on the signal transduction. Ellipsometric measurements evidenced that the swelling of PHEMA films with intermediate molecular weight at 80% RH follows Fickian diffusion mechanism. Nevertheless, due to the weak optical contrast or film homogeneity shorter or longer chains than PHEMA-300 could not be investigated by ellipsometry. PHEMA films deposited onto PS surfaces presented dewetting, which limited the ellipsometric measurements. In comparison to ellipsometry, monitoring swelling behavior of PHEMA by nanomechanical responses is more advantageous because it is faster and less restricted.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations鈥揷itations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright 漏 2024 scite LLC. All rights reserved.
Made with 馃挋 for researchers
Part of the Research Solutions Family.