Objective: Surface electromyography (sEMG) is a noninvasive option for monitoring respiratory effort in ventilated patients. However, respiratory sEMG signals are affected by crosstalk and cardiac activity. This work addresses the blind source separation (BSS) of inspiratory and expiratory electrical activity in single- or two-channel recordings. The main contribution of the presented methodology is its applicability to the addressed muscles and the number of available channels. Approach: We propose a two-step procedure consisting of a single-channel cardiac artifact removal algorithm, followed by a single- or multi-channel BSS stage. First, cardiac components are removed in the wavelet domain. Subsequently, a nonnegative matrix factorization (NMF) algorithm is applied to the envelopes of the resulting wavelet bands. The NMF is initialized based on simultaneous standard pneumatic measurements of the ventilated patient. Main results: The proposed estimation scheme is applied to twelve clinical datasets and simulated sEMG signals of the respiratory system. The results on the clinical datasets are validated based on expert annotations using invasive pneumatic measurements. In the simulation, three measures evaluate the separation success: The distortion and the correlation to the known ground truth and the inspiratory-to-expiratory signal power ratio. We find an improvement across all SNRs, recruitment patterns, and channel configurations. Moreover, our results indicate that the initialization strategy replaces the manual matching of sources after the BSS. Significance: The proposed separation algorithm facilitates the interpretation of respiratory sEMG signals. In crosstalk affected measurements, the developed method may help clinicians distinguish between inspiratory effort and other muscle activities using only noninvasive measurements.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.