The present study tested the shear bond strength (SBS) of orthodontic brackets bonded to teeth using flowable resins. A total of 105 human teeth were divided into seven groups. The brackets in each group were bonded to the tooth substrates using a Transbond XT adhesive and six other different flowable resins, respectively. Each adhesive resin was light-cured using a quartz-tungsten-halogen (QTH) light for 40 seconds. The brackets were debonded in shear mode using a universal testing machine. The brackets bonded using Tetric Flow and Grandio Flow showed slightly greater SBS values (13.0±1.8 and 12.2±1.2 MPa, respectively) than the Transbond XT adhesive (12.1±1.2 MPa). However, the SBS values of Transbond XT, X-flow, Tetric Flow, Grandio Flow, and Filtek Z350 flow were not significantly different. As for Admira Flow and Aelite Flow, they scored significantly lower SBS values (7.0±2.1 and 9.2±1.3 MPa, respectively) than the other groups. On bracket failure mode, statistical analysis revealed a similar failure mode among all the seven test groups.
This study evaluated the polymerization shrinkage, flexural and compressive properties of low-shrinkage resin composites. For the study, four methacrylate-based and one silorane-based resin composites were light cured using three different light-curing units (LCUs) and their polymerization shrinkage, flexural (strength (FS) and modulus (FM)) and compressive (strength (CS) and modulus (CM)) properties were evaluated. Data were statistically analyzed using ANOVA and a post-hoc Tukey test. The polymerization shrinkage ranged approximately 7.6-14.2 μm for 2-mm thick specimens depending on the resin product and LCU. Filtek LS showed the least shrinkage while the rest shrank approximately 13.2-14.2 μm. However, Filtek LS showed the greatest shrinkage difference for the used LCUs. FS and CS of the tested specimens ranged 96.2-152.1 MPa and 239.2-288.4 MPa, respectively, depending on the resin product and LCU. The highest and lowest FS and FM were recorded for the methacrylate-based resin composites. Among the specimens, Filtek LS showed the lowest CS and CM.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.