Mechanical forces are central to developmental, physiological and pathological processes1. However, limited understanding of force transmission within sub-cellular structures is a major obstacle to unravelling molecular mechanisms. Here we describe the development of a calibrated biosensor that measures forces across specific proteins in cells with pico-Newton (pN) sensitivity, as demonstrated by single molecule fluorescence force spectroscopy2. The method is applied to vinculin, a protein that connects integrins to actin filaments and whose recruitment to focal adhesions (FAs) is force-dependent3. We show that tension across vinculin in stable FAs is ~2.5 pN and that vinculin recruitment to FAs and force transmission across vinculin are regulated separately. Highest tension across vinculin is associated with adhesion assembly and enlargement. Conversely, vinculin is under low force in disassembling or sliding FAs at the trailing edge of migrating cells. Furthermore, vinculin is required for stabilizing adhesions under force. Together, these data reveal that FA stabilization under force requires both vinculin recruitment and force transmission, and that, surprisingly, these processes can be controlled independently.
Programmed connection of amino acids or nucleotides into chains introduced a revolution in control of biological function. Reacting proteins together is more complex because of the number of reactive groups and delicate stability. Here we achieved sequenceprogrammed irreversible connection of protein units, forming polyprotein teams by sequential amidation and transamidation. SpyTag peptide is engineered to spontaneously form an isopeptide bond with SpyCatcher protein. By engineering the adhesin RrgA from Streptococcus pneumoniae, we developed the peptide SnoopTag, which formed a spontaneous isopeptide bond to its protein partner SnoopCatcher with >99% yield and no crossreaction to SpyTag/SpyCatcher. Solid-phase attachment followed by sequential SpyTag or SnoopTag reaction between building-blocks enabled iterative extension. Linear, branched, and combinatorial polyproteins were synthesized, identifying optimal combinations of ligands against death receptors and growth factor receptors for cancer cell death signal activation. This simple and modular route to programmable "polyproteams" should enable exploration of a new area of biological space.synthetic biology | protein engineering | nanobiotechnology | split protein | antibody
Recent development and applications of calibrated, FRET-based tension sensors have led to a new understanding of single molecule mechanotransduction in a number of biological systems. To expand the range of accessible forces, we systematically measured FRET vs. force trajectories for 25, 40 and 50 amino acid peptide repeats derived from spider silk. Single molecule fluorescence-force spectroscopy showed that the peptides behaved as linear springs instead of the nonlinear behavior expected for a disordered polymer. Our data are consistent with a compact, rod-like structure that measures 0.26 nm per 5 amino acid repeat that can stretch by 500% while maintaining linearity, suggesting that the remarkable elasticity of spider silk proteins may in part derive from the properties of individual chains. We found the shortest peptide to have the widest range of force sensitivity: between 2 pN and 11 pN. Live cell imaging of the three tension sensor constructs inserted into vinculin showed similar force values around 2.4 pN. We also provide a lookup table for force vs intracellular FRET for all three constructs.
Purine riboswitches are RNA regulatory elements that control purine metabolism in response to intracellular concentrations of the purine ligands. Conformational changes of the guanine riboswitch aptamer domain induced by guanine binding lead to transcriptional regulation of genes involved in guanine biosynthesis. The guanine riboswitch aptamer domain has three RNA helices designated P1, P2, and P3. An overall model for the Mg2+- and guanine-dependent relative orientations and dynamics of P1, P2, and P3 has not been reported, and the conformational role of guanine under physiologically relevant conditions has not been fully elucidated. In this study, an ensemble and single-molecule fluorescence resonance energy transfer (FRET) study was performed on three orthogonally labeled variants of the xpt guanine riboswitch aptamer domain. The combined FRET data support a model in which the unfolded state of the aptamer domain has a highly dynamic P2 helix that switches rapidly between two orientations relative to nondynamic P1 and P3. At ≪1 mM Mg2+ (in the presence of a saturating level of guanine) or ≥1 mM Mg2+ (in the absence of guanine), the riboswitch starts to adopt a folded conformation in which loop−loop interactions lock P2 and P3 into place. At >5 mM Mg2+, further compaction occurs in which P1 more closely approaches P3. Our data help to explain the biological role of guanine as stabilizing the globally folded aptamer domain conformation at physiologically relevant Mg2+ concentrations (≤1 mM), whereas in the absence of guanine, much higher Mg2+ concentrations are required to induce this folding event.
Mechanical tension plays a large role in cell development ranging from morphology to gene expression. On the molecular level, the effects of tension can be seen in the dynamic arrangement of membrane proteins as well as the recruitment and activation of intracellular proteins. Forces applied to biopolymers during in vitro force measurements offer greater understanding of the effects of tension on molecules in live cells, and experimental techniques involving test tubes and live cells can often overlap. Indeed, when forces exerted on cellular components can be calibrated ex vivo with force spectroscopy, a powerful tool is available for researchers in probing cellular mechanotransduction on the molecular scale. This review will discuss the techniques used in measuring both cellular traction forces and single‐molecule force spectroscopy. Emphasis will be placed on the use of fluorescence reporter systems for the development of in vivo tension sensors that can be used for calibration with single molecule force methods. © 2011Wiley Periodicals, Inc. Biopolymers 95: 332–344, 2011.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.