Background: Herpes simplex virus (HSV) replication can be detected in the respiratory secretions of a high proportion of ventilated intensive care unit (ICU) patients. However, the clinical significance remains poorly defined. We investigated whether patients with ventilator-associated pneumonia not responding to antibiotics and in whom high levels of HSV could be detected in respiratory secretions benefit from acyclovir treatment. Methods: Respiratory secretions (bronchoalveolar lavage fluid or tracheal aspirates) were tested for HSV replication by quantitative real-time PCR. ICU survival times, clinical parameters, and radiographic findings were retrospectively compared between untreated and acyclovir treated patients with high (> 10 5 HSV copies/mL) and low (10 3 -10 5 HSV copies/mL) viral load.Results: Fifty-seven low and 69 high viral load patients were identified. Fewer patients with high viral load responded to antibiotic treatment (12% compared to 40% of low load patients, p = 0.001). Acyclovir improved median ICU survival (8 vs 22 days, p = 0.014) and was associated with a significantly reduced hazard ratio for ICU death (HR = 0.31, 95% CI 0.11-0.92, p = 0.035) in high load patients only. Moreover, circulatory and pulmonary oxygenation function of high load patients improved significantly over the course of acyclovir treatment: mean norepinephrine doses decreased from 0.05 to 0.02 μg/kg body weight/min between days 0 and 6 of treatment (p = 0.049), and median PaO 2 /FiO 2 ratio increased from 187 to 241 between day 3 and day 7 of treatment (p = 0.02). Chest radiographic findings also improved significantly (p < 0.001). Conclusions: In patients with ventilator-associated pneumonia, antibiotic treatment failure, and high levels of HSV replication, acyclovir treatment was associated with a significantly longer time to death in the ICU and improved circulatory and pulmonary function. This suggests a causative role for HSV in this highly selected group of patients.
The diagnostic efficacy of intra-articular MRA in most clinical conditions affecting major joints is greater than that of plain MRI. In some diagnostic problems MRA achieves almost the same sensitivity and specificity as the surgical gold standard. Given a sterile application, the intra-articular administration of Gd-DTPA in a concentration of 2 mmol/l prior to MRI is a safe procedure.
In dual-energy CT datasets, the conspicuity of liver metastases can be enhanced by virtual monoenergetic imaging (VMI) reconstructions at low keV levels. Our study investigated whether this effect can be reproduced in photon-counting detector CT (PCD-CT) datasets. We analyzed 100 patients with liver metastases who had undergone contrast-enhanced CT of the abdomen on a PCD-CT (n = 50) or energy-integrating detector CT (EID-CT, single-energy mode, n = 50). PCD-VMI-reconstructions were performed at various keV levels. Identical regions of interest were positioned in metastases, normal liver, and other defined locations assessing image noise, tumor-to-liver ratio (TLR), and contrast-to-noise ratio (CNR). Patients were compared inter-individually. Subgroup analyses were performed according to BMI. On the PCD-CT, noise and CNR peaked at the low end of the keV spectrum. In comparison with the EID-CT, PCD-VMI-reconstructions exhibited lower image noise (at 70 keV) but higher CNR (for ≤70 keV), despite similar CTDIs. Comparing high- and low-BMI patients, CTDI-upregulation was more modest for the PCD-CT but still resulted in similar noise levels and preserved CNR, unlike the EID-CT. In conclusion, PCD-CT VMIs in oncologic patients demonstrated reduced image noise–compared to a standard EID-CT–and improved conspicuity of hypovascularized liver metastases at low keV values. Patients with higher BMIs especially benefited from constant image noise and preservation of lesion conspicuity, despite a more moderate upregulation of CTDI.
This pilot study shows that FDG-PET is a promising diagnostic tool for patients with painful knee prostheses. There is a good correlation between PET images and the intraoperative and pathology findings. Its clinical value, however, warrants further evaluation in a larger patient population.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.